MITSUBISHI L02CPU-P MELSAP-L Manual L02CPU-P Programming Manual

Brand: MITSUBISHI
Product model: L02CPU-P
Name: PLC
Sort: Programming Manual (MELSAP-L)
File language: English
File size: 0.00MB
Input points: 16 points.
Rated input voltage: AC100 ~ 120V.
Common way: 16 point / public end.
Input / output occupied points: 16 points (I/O distribution: 16 points).
External wiring connection: 18 point terminal.
The input and output module is also called control module, which can output signal when there is control requirement,
Or provide a switch signal to the controlled device,
At the same time, the feedback signal of the equipment can be received to report to the host computer,
Is an important part of the fire alarm linkage system,
The input and output modules in the market can provide a pair of passive normally open / normally closed contacts,
For controlling the controlled equipment, the module of the part can be set by the parameters,
Set to active output, corresponding to the two input and output modules, multiple input and output modules, and so on L02CPU-P MELSAP-L Manual L02CPU-P Programming Manual L02CPU-P MELSAP-L Manual L02CPU-P Programming Manual L02CPU-P AnyWireASLINK master station.
Transmission distance: the longest 200m.
Data input and output: up to 512 points.
Connect up to 128 units.
Enter 256 points, 256 points out of the output.
Connecting the input and output of the sensor to the programmable controller L02CPU-P MELSAP-L Manual L02CPU-P Programming Manual.
Ultra small sensor can be freely configured to control the input and output of 512 points.
In addition, the sensor can be supplied with a AnyWireASLINK transmission line (2 lines) by means of communication,
So as to facilitate additional sensor.
And can also be through the engineering software Works2 GX batch management sensor disconnection detection and from the station module settings, etc.,
Can significantly reduce the engineering hours.
Basic composition.
AnyWireASLINKAnyWireASLINK can be selected according to the load current of 2 wire or 4 wire from the station module.
In addition to the 2 wire type, the local power supply can be connected with the 4 wire type mixed use L02CPU-P MELSAP-L Manual L02CPU-P Programming Manual.
2 wire type.
The load current is less than that of the hour, by using the non isolated 2 wire type from the station module,
Easy connection without using local power suupply L02CPU-P MELSAP-L Manual L02CPU-P Programming Manual.
4 wire type
By using isolated 4 wire type from the station module, the local power supply can be used,
Can support the use of more current load.
Related products
MITSUBISHI
cpu module
L02CPU-P
MITSUBISHI cpu module L02CPU-P
"Universal output function: source type. Prog
MITSUBISHI
cpu module
L26CPU-PBT
MITSUBISHI cpu module L26CPU-PBT
"Universal output function: source type. Prog
MITSUBISHI
cpu module
L02SCPU-P
MITSUBISHI cpu module L02SCPU-P
"Universal output function: source type. Prog
MITSUBISHI
cpu module
L26CPU-P
MITSUBISHI cpu module L26CPU-P
"Universal output function: source type. Prog