MITSUBISHI inverter FR-A720 series.
Voltage level: 3 phase 200V.
Frequency converter capacity: 0.4KW.
Inverter output for the PWM wave, containing more harmonic.
Frequency conversion power sensor through the input voltage and current signals to exchange sampling,
Sampling value through cable, optical fiber and other transmission systems and digital input frequency conversion power analyzer,
The sampling value of the voltage and current is calculated by the digital input frequency conversion power analyzer,
It can obtain the parameters such as voltage effective value, current effective value, fundamental wave voltage, fundamental current, harmonic voltage, harmonic current, active power, fundamental wave power and harmonic power FX3UC-4AD Analog Control Edition Manual FX3UC-4AD USER'S MANUAL FX3UC-4AD Analog Control Edition Manual FX3UC-4AD USER'S MANUAL
FX3UC-4AD Power: 560kw.
Voltage: 400V.
The power factor of the input power factor is up to 0.99 and above (100% load).
Can be connected to multiple inverters, to achieve a common DC bus mode.
Equipped with standard power retrogradation function. "MITSUBISHI inverter FR-F740 series.
Voltage level: three phase 400V.
Frequency converter capacity: 5.5KW.
The use of frequency converter motor is in order to speed, and reduce the starting current FX3UC-4AD Analog Control Edition Manual FX3UC-4AD USER'S MANUAL.
In order to produce a variable voltage and frequency, the device is the first power of the AC power conversion to DC (DC), the process is called rectification.
The direct current (DC) is transformed into alternating current (AC) and its scientific term is "inverter" (inverter).
General inverter is the DC power supply inverter for a certain fixed frequency and a certain voltage of the inverter.
For the inverter as the frequency adjustable, adjustable voltage inverter, we called the inverter. "Maximum file size: 512MB.
Data form: CSV form.
Weight: 0.3kg.
PLC data can be saved in the form of CF to CSV.
1, can save up to 254, 32767 row of data.
2, save the CSV file can be read through the table count software, and in the form of graphics display, ease of analysis.
PLC can be read through the collected data.
Long time to collect data, through the file FIFO function,
You can automatically generate new files and automatically overwrite the old files, to achieve the continuous collection of data.
Record the hisstorical data before and after the alarm,
In a file to collect data buffer storage file will play a FX3UC-4AD Analog Control Edition Manual FX3UC-4AD USER'S MANUAL.
FX3U, FX3UC version 2.61 or more can be used, the need to connect the FX3U when the expansion board FX3UC-4AD Analog Control Edition Manual FX3UC-4AD USER'S MANUAL.
The communication function expansion board and the communication special adapter are the same, the communication occupies 1 channels.