MITSUBISHI FX3U-ENET Manual FX3U-ENET INSTALLATION MANUAL

Brand: MITSUBISHI
Product model: FX3U-ENET
Name: Special unit
Sort: INSTALLATION MANUAL
File language: English
File size: 0.31MB
Apply PLC:FX2N (up to 3 units), FX3U (up to 3 units).
Applicable PLC:FX2NC (to FX2NC-CNV-IF, up to 1 units), FX3UC (to FX2NC-CNV-IF or FX3UC-1PS-5V, up to 3 units).
The rotation angle detecting unit is controlled by the mechanical cam switch,
The rotation angle is detected by using the special detector, and the rotation position control with high precision is realized FX3U-ENET Manual FX3U-ENET INSTALLATION MANUAL FX3U-ENET
Using the setting unit, it is easy to realize the setting and monitoring of the action resolution.
The detection of rotation angle can be accurate to the high accuracy of 415rpm/0.5 degree or 830rpm/1.0 degree unit.
Built without battery to maintain the EEPROM, the maximum can store 8 kinds of procedures.
The cable that is assembled in the device without the brush can be extended to 100m FX3U-ENET Manual FX3U-ENET INSTALLATION MANUAL.
When used alone, the CC-LINK type FX2N-32CCL interface module can be used to connect to the CC-LINK system.
Product composition:
FX2N-1RM: the main body of programmable cam switch (with setting panel).
F2-720RSV: no brush splitter.
FX2N-RS-5CAB: splitter cable (5m).
PLC connecting cable (55mm). Power: 7.5kw.
Purpose: high frequency braking resistor FX3U-ENET Manual FX3U-ENET INSTALLATION MANUAL.
The use rate of the built-in regenerative brake of the transducer can be promoted.
When using the FR-ABR type brake resistor, the short circuit piece between the terminal PR-PX is removed. Does not remove the short circuit chip will lead to overheating of the brake resistor.
The utilization rate of the regenerative braking should be less than the allowable brake use rate in the above table.
With the operating frequency of the brake resistor to reach 300 degrees C or higher, it is necessary to take protective measures and cooling.
MYS type resistor can be used. But please pay attention to the allowable brake use rate.
Do not remmove the terminal P/+ and P1 between the short circuit chip, in addition to connecting the DC reactor FX3U-ENET Manual FX3U-ENET INSTALLATION MANUAL.
The installation of thermal relay, to avoid overheating and burn the braking resistor. Function: RRS-485 communication FX3U-ENET Manual FX3U-ENET INSTALLATION MANUAL.
Adapter for connecting the left extension function of the CPU module.
CPU module can be connected to the left side up to 6 units.
Related products
MITSUBISHI
PLC
FX3UC-96MT/DSS
MITSUBISHI PLC FX3UC-96MT/DSS
Input and output points: 96 points. Input poi
MITSUBISHI
PLC
FX3U-16MT/DSS
MITSUBISHI PLC FX3U-16MT/DSS
Max input / output points: 16 points. Power s
MITSUBISHI
PLC
FX3U-32MR/ES-A
MITSUBISHI PLC FX3U-32MR/ES-A
Max input / output points: 32 points. Supply
MITSUBISHI
PLC
FX3UC-16MR/D-T
MITSUBISHI PLC FX3UC-16MR/D-T
Input and output points: 16 points. Input poi