Input and output points: 14 points.
Power supply: AC100-240V.
Input points: 8 points.
Output points: 6 points.
Output form: transistor output (source).
Power consumption: 19W.
Weight: 0.3KG.
Outline dimension: 60x90x49mm.
Built in CPU, power supply, input and output.
Keep FX1S compact body, while adding more features FX3U-32MT/ESS Hardware Edition Manual FX3U-32MT/ESS USER'S MANUAL.
Special adaptor and function expansion board can be installed and used FX3 series
FX3U-32MT/ESS
High speed operation.
Basic instructions: 0.21 s/ instruction
Application instruction: 0.5 s/ instruction
Large capacity memory.
Built in program memory 4000 steps.
No battery.
Auxiliary relay: 1536 points.
Timer: 138 points.
Counter: 67.
Data register: 3000.
A new application model.
FX3SA is a basic model on the basis of the basic performance of the FX1S increased the expansion of the new models FX3U-32MT/ESS Hardware Edition Manual FX3U-32MT/ESS USER'S MANUAL.
FX3SA is suitable for all kinds of fields, such as analog quantity, Ethernet, MODBUS function, small scale equipment and so on.
Basic models suitable for small scale control.
Compact but powerful,
At the same time, the analog quantity and the communication function and so on. Total input and output points: 8 points FX3U-32MT/ESS Hardware Edition Manual FX3U-32MT/ESS USER'S MANUAL.
Output points: 8 points.
Output type: relay output.
FX Series in the compact body built in superior performance, and strive to operate simple.
In addition, rich options can meet the various needs of customers.
In the virtual factory will be rich in the function of a part of the introduction.
It is easy to control the analog quantity of the application.
Can be extended to all models in the FX series analog devices.
Function extension board, special adapter without programming can be used for communication.
FX2N extension module.
The expansion module is an input and output expansion device of the power supply from the basic unit or thee expansion unit,
Can choose the relay or crystal output models, to 8 points for the unit to connect FX3U-32MT/ESS Hardware Edition Manual FX3U-32MT/ESS USER'S MANUAL.
Can be extended to FX3GA/FX3G, FX3GE, FX3GC, as well as FX3U, FX3UC series,
When connecting to FX3UC or FX3GC, you need FX2NC-CNV-IF or FX3UC-1PS-5V FX3U-32MT/ESS Hardware Edition Manual FX3U-32MT/ESS USER'S MANUAL.
The number of connection points depends on the basic unit and the expansion unit.