Max input / output points: 10 points.
Power supply voltage: DC24V.
Input points: 6 points.
Output points: 4 points.
Output type: relay.
Power consumption (W): 19.
Weight (kg):0.3.
Size (WxHxD) mm:60x90x75.
Positioning and pulse output functions: a PLC cell can output 2 point 100KHz pulses at the same time FX3U-32MT/DSS MODBUS Serial Communication Edition Manual FX3U-32MT/DSS USER'S MANUAL.
PLC is equipped with 7 special positioning instructions,
Including zero return, absolute or relative address expression and special pulse output control
FX3U-32MT/DSS
Host has 10 points (6I/4O), 14 points (8I/6O), 20 points (12I/8O), 30 points (16I/14O) of 4 types.
This type of PLC is mainly used in all of the digital input, digital output control point of the device.
Can be directly connected to the 220V city power, built-in 8K step EEPROM memory, no battery, easy to maintain FX3U-32MT/DSS MODBUS Serial Communication Edition Manual FX3U-32MT/DSS USER'S MANUAL.
The series transistor output (MT) of the PLC, can be output 2 100KHz pulse, direct drive servo or stepper motor.
The series PLC can not be brought with the expansion module, but can be installed by the BD board to extend a small amount of I/O.
The series 1N through the installation of BD series PLC board, can achieve RS232, RS485, RS422 communication FX3U-32MT/DSS MODBUS Serial Communication Edition Manual FX3U-32MT/DSS USER'S MANUAL. Power: 15kw.
Voltage: 200V.
The power factor of the input power factor is up to 0.99 and above (100% load).
Can be connected to multiple inverters, to achieve a common DC bus mode.
Equipped with standard power retrogradation function. The connector is converted to a screw relay terminal.MITSUBISHI inverter series: FR-A820.
Voltage level: three phase 200V.
Power: 2.2kw.
SLD converter rated current: 16.7A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
Parameters can be selected by 4 different rated current and different overload rating (SLD (ultra light load) rated, LD (light load) rating, ND (general load) rating, HD (weight).
Type load) for selection.
You can choose the most suitable frequency converter for use; and by selecting a transducer with a SLD or LD rated level,
Be able to reduce the size of the device (compared with the FR-A700 series, to reduce the volume of equipment).
For appllications that require high torque at low speeds, the HD rating is the most suitable FX3U-32MT/DSS MODBUS Serial Communication Edition Manual FX3U-32MT/DSS USER'S MANUAL.
The controller is used to control and monitor the frequency converter through the network FX3U-32MT/DSS MODBUS Serial Communication Edition Manual FX3U-32MT/DSS USER'S MANUAL.
Standard corresponding RS-485 communication (MITSUBISHI converter protocol, Modbus-RTU protocol) data transmission speed up to 115200bps.