MITSUBISHI
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI FX2NC-16MT-DSS Manual FX2NC-16MT-DSS PROGRAMMING MANUAL II

MITSUBISHI FX2NC-16MT-DSS Manual FX2NC-16MT-DSS PROGRAMMING MANUAL II

Brand: MITSUBISHI
Product model: FX2NC-16MT-DSS
Name: PLC
Sort: PROGRAMMING MANUAL II
File language: English
File size: 7.09MB
MITSUBISHI inverter FR-D740 series.
Voltage level: three phase 400V.
Frequency converter capacity: 5.5KW.
The internal and back of the inverter structure considering the cooling effect, the relationship between the upper and lower ventilation is also important,
Therefore, in order for the type of unit, hanging on the wall to the vertical position, the installation of vertical as possible FX2NC-16MT-DSS Manual FX2NC-16MT-DSS PROGRAMMING MANUAL II FX2NC-16MT-DSS
Transducer can be used to drive a single phase motor? Can single phase power supply be used?
Basically can not be used. For a single phase motor with governor switch, the auxiliary winding will be burnt when the speed is below the operating point;
For the capacitor start or capacitor operation mode, the capacitor explosion will be induced FX2NC-16MT-DSS Manual FX2NC-16MT-DSS PROGRAMMING MANUAL II.
The inverter power supply is usually 3, but the capacity for small, single-phase power is also useful functioning aircraft. MITSUBISHI inverter FR-A740 series.
Voltage level: 3 phase 400V.
Frequency converter capacity: 162KW.
Frequency converter is the application of frequency conversion technology and micro electronics technology, by changing the motor operating power frequency mode to control the AC motor power control equipment FX2NC-16MT-DSS Manual FX2NC-16MT-DSS PROGRAMMING MANUAL II.
The converter is composed of rectifier (AC), filter, inverter (DC), braking unit, driving unit, micro processing unit of the detection unit.
Inverter by the internal IGBT to adjust the output power supply voltage and frequency,
According to the actual needs of the motor to provide the required power supply voltage, and then achieve the purpose of energy saving, speed control, in addition to the,
Inverter has a lot of protection functions, such as over current, over voltage, overload protection and so on. "MITSUBISHI inverter FR-F740P series.
Voltage level: three phase 400V.
Frequency converter capacity: 500KW.
The main circuit of the inverter can be divided into two categories in general: voltage type is the voltage source of the DC converter for AC inverter,
The filtering of the DC circuit is the capacitance; the current mode is the DC conversion of the current source to the AC inverter,
The DC loop filter is the inductor.
It is based on the overall effect of three-phase waveform generation,
In order to approach the ideal circular rotating magnetic field in the air gap of the motor,
A generation phase modulation waveform control inscribesthe polygon to approach the circle way.
After practice, it has been improved, that is, the introduction of frequency compensation, can eliminate the error of speed control;
By feedback estimation of flux amplitude, eliminating the influence of stator resistance at low speed, the output voltage and current closed loop,
In order to improve the accuracy and stability of the dynamic.
But there are many control circuit, and no torque is introduced, so the system performance has not been improved.
Frequency converter is a power control device which uses the power of the power semiconductor device to change the power frequency to another frequency,
Can realize the asynchronous motor soft start, variable frequency speed regulation, improve the operation precision, change the power factor, over current / over voltage / overload protection and other functions.
The use of frequency converter motor is in order to speed, and reduce the starting current.
In order to produce a variable voltage and frequency,
The equipment to the power of the AC power conversion to DC (DC), the process is called rectification.
The direct current (DC) is transformed into alternating current (AC) and its scientific term is "inverter" (inverter).
General inverter is the DC power supply inverter for a certain fixed frequency and a certain voltage of the inverter.
For the inverter as the frequency adjustable, adjustable voltage inverter, we called the inverter.
Inverter output waveform is simulated sine wave,
Is mainly used in three-phase asynchronous motor speed control, and also called frequency governor.
For the variable frequency inverter, which is mainly used in the testing equipment of instrument and meter,
To sort out the waveform, you can output the standard sine wave, called the inverter power supply FX2NC-16MT-DSS Manual FX2NC-16MT-DSS PROGRAMMING MANUAL II.
The general inverter is 1520 times inverter price.
The main device called "inverter" because of the voltage or frequency of the inverter device ",
Therefore, the product itself is named "inverter", that is: inverter FX2NC-16MT-DSS Manual FX2NC-16MT-DSS PROGRAMMING MANUAL II. "
Related products
MITSUBISHI
Connecting cable
FX2NC-100MPCB
MITSUBISHI Connecting cable FX2NC-100MPCB
Use: power cord for asic unit. Length: 1.0m.
MITSUBISHI
Extension module
FX2NC-16EX-DS
MITSUBISHI Extension module FX2NC-16EX-DS
Input points: 16 points. Power supply: the a
MITSUBISHI
High speed counter module
FX2NC-1HC
MITSUBISHI High speed counter module FX2NC-1HC
Maximum frequency: 50kHz. Input points: 1 poi
MITSUBISHI
Input module
FX2NC-16EX
MITSUBISHI Input module FX2NC-16EX
Function: no terminal input. Input points: 16