MITSUBISHI inverter series: FR-A820.
Voltage level: three phase 200V.
Power: 5.5kw.
SLD converter rated current: 34A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
Parameters can be selected by 4 different rated current and different overload rating (SLD (ultra light load) rated, LD (light load) rating, ND (general load) rating, HD (weight) FX2N-232IF Data Communication Edition Manual FX2N-232IF USER'S MANUAL
FX2N-232IF
Type load) for selection.
You can choose the most suitable frequency converter for use; and by selecting a transducer with a SLD or LD rated level,
Be able to reduce the size of the device (compared with the FR-A700 series, to reduce the volume of equipment).
For applications that require high torque at low speeds, the HD rating is the most suitable FX2N-232IF Data Communication Edition Manual FX2N-232IF USER'S MANUAL.
The controller is used to control and monitor the frequency converter through the network.
Standard corresponding RS-485 communication (MITSUBISHI converter protocol, Modbus-RTU protocol) data transmission speed up to 115200bps. Connecting cable for handheld GOT and PLC.
Cable length: 10 meters.
Application: RS-422 connection and RS-232C connection. Input / output type: transistor output (source) FX2N-232IF Data Communication Edition Manual FX2N-232IF USER'S MANUAL.
Output points: 16 points.
DC5V internal consumption current: 100mA.
DC24V internal consumption current: 125mA.
In order to extend the input output of the device.
Also has a built-in power supply products.
The maximum number of points for the input and output is 256.
Expansion module: up to 16 units (in addition to the power expansion module)
The total number of CC-Link, AnyWireASLINK, and Bitty series of remote I/O is 512 points. Convert connectors to e-CON.Connecting cable for handheld GOT and PLC.
Cable length: 3 meters.
Application: RS-422 connection. Max input / output points: 60 points.
Supply voltage: 100 - 240VAC.
Input points: 36 points.
Output points: 24 points.
Output type: Transistor (source).
Power consumption (W): 35.
Weight (kg):0.8.
Size (WxHxD) mm:175x90x75.
Terminal row type standard machine with extended input output
Can also be less of a system with analog or communication, etc..
CPU, power supply, input and output integration.
Display module or function expansion board can be less installed.
In addition, you can also reduce the input output or special module.
Built in 8000 step EPROM memory.
No battery. Maintenance free.
Overseas oriented products meet all kinds of international standards.
FX1N series is a very powerful micro PLC, can be extended to up to 128 I/O points,
And can increase the special function module or the expansion board.
Communication and data link function options make FX1N in tthe volume, communication and special function modules and other important applications is very perfect FX2N-232IF Data Communication Edition Manual FX2N-232IF USER'S MANUAL.
A PLC unit can output 2 100KHz pulses at the same time,
PLC is equipped wiith 7 special positioning instructions,
Including zero return, absolute position readout, absolute or relative drive, and special pulse output control FX2N-232IF Data Communication Edition Manual FX2N-232IF USER'S MANUAL.