Brand: MITSUBISHI
Product model: FX1S-14MT-001
Name: PLC
Sort: PROGRAMMING MANUAL II
File language: English
File size: 7.09MB
MITSUBISHI inverter series: FR-A820.
Voltage level: three phase 200V.
Power: 2.2kw.
SLD converter rated current: 16.7A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
Parameters can be selected by 4 different rated current and different overload rating (SLD (ultra light load) rated, LD (light load) rating, ND (general load) rating, HD (weight) FX1S-14MT-001 Manual FX1S-14MT-001 PROGRAMMING MANUAL II FX1S-14MT-001
Type load) for selection.
You can choose the most suitable frequency converter for use; and by selecting a transducer with a SLD or LD rated level,
Be able to reduce the size of the device (compared with the FR-A700 series, to reduce the volume of equipment).
For applications that require high torque at low speeds, the HD rating is the most suitable FX1S-14MT-001 Manual FX1S-14MT-001 PROGRAMMING MANUAL II.
The controller is used to control and monitor the frequency converter through the network.
Standard corresponding RS-485 communication (MITSUBISHI converter protocol, Modbus-RTU protocol) data transmission speed up to 115200bps. Input and output points: 30 points.
Power supply: AC100-240V.
Input points: 16 points.
Output points: 14 points.
Output form: transistor output (drain) FX1S-14MT-001 Manual FX1S-14MT-001 PROGRAMMING MANUAL II.
Power consumption: 21W.
Weight: 0.45KG.
Outline dimension: 100x90x75mm.
A new application model.
FX3SA is a basic model on the basis of the basic performance of FX1S above the expansion of the expansion of the new model.
FX3SA is applicable to all kinds of fields of small scale equipment which need to simulate the quantity and function of MODBUS and Ethernet.
Basic models suitable for small scale control.
Compact but powerful,
At the same time, the analog quantity and communication function, etc.. "MITSUBISHI inverter FR-F740P series.
Voltage level: three phase 400V.
Frequency converter capacity: 560KW.
The main circuit of the inverter can be divided into two categories in general: voltage type is the voltage source of the DC converter for AC inverter,
The filtering of the DC circuit is the capacitance; the current mode is the DC conversion of the current source to the AC inverter,
The DC loop filter is the inductor.
It is based on the overall effect of three-phase waveform generation,
In order to approach the ideal circular rotating magnetic field in the air gap of the motor,
A generation phase modulation waveform control inscribesthe polygon to approach the circle way.
After practice, it has been improved, that is, the introduction of frequency compensation, can eliminate the error of speed control;
By feedback estimation of flux amplitude, eliminating the influence of stator resistance at low speed, the output voltage and current closed loop,
In order to improve the accuracy and stability of the dynamic.
But there are many control circuit, and no torque is introduced, so the system performance has not been improved.
Frequency converter is a power control device which uses the power of the power semiconductor device to change the power frequency to another frequency,
Can realize the asynchronous motor soft start, variable frequency speed regulation, improve the operation precision, change the power factor, over current / over voltage / overload protection and other functions.
The use of frequency converter motor is in order to speed, and reduce the starting current.
In order to produce a variable voltage and frequency,
The equipment to the power of the AC power conversion to DC (DC), the process is called rectification.
The direct current (DC) is transformed into alternating current (AC) and its scientific term is "inverter" (inverter).
General inverter is the DC power supply inverter for a certain fixed frequency and a certain voltage of the inverter.
For the inverter as the frequency adjustable, adjustable voltage inverter, we called the inverter.
Inverter output waveform is simulated sine wave,
Is mainly used in three-phase asynchronous motor speed control, and also called frequency governor.
For the variable frequency inverter, which is mainly used in the testing equipment oof instrument and meter,
To sort out the waveform, you can output the standard sine wave, called the inverter power supply FX1S-14MT-001 Manual FX1S-14MT-001 PROGRAMMING MANUAL II.
The general inverter is 1520 times inverter price.
The main device called "inverter" because of the voltage or frequency of the inverter device ",
Therefore, the product itself is named "inverter", that is: inverter FX1S-14MT-001 Manual FX1S-14MT-001 PROGRAMMING MANUAL II. "
Related products
MITSUBISHI
PLC
FX1S-10MR-001
MITSUBISHI PLC FX1S-10MR-001
Total points: 10 points. Input points: 6 poin
MITSUBISHI
PLC
FX2N-32MT-001
MITSUBISHI PLC FX2N-32MT-001
Max input / output points: 32 points. Supply
MITSUBISHI
PLC
FX1S-10MT-DSS
MITSUBISHI PLC FX1S-10MT-DSS
Max input / output points: 10 points. Power s
MITSUBISHI
PLC
FX1S-10MT-D
MITSUBISHI PLC FX1S-10MT-D
Max input / output points: 10 points. Power s