MITSUBISHI
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI FX1N SERIES Manual FX1N SERIES HARDWARE MANUAL

MITSUBISHI FX1N SERIES Manual FX1N SERIES HARDWARE MANUAL

Brand: MITSUBISHI
Product model: FX1N SERIES
Name: PLC
Sort: HARDWARE MANUAL
File language: English
File size: 2.00MB
The built-in I/O function (Location: 1 axis) of the pulse output is converted to a differential drive output.Signal level: the DC5V, 12V, and 24V differential output can be connected to the DC5V terminal by connecting terminals.
Applicable PLC:FX1N, FX2N, FX3U, FX2NC (to FX2NC-CNV-IF).
Applicable PLC:FX3UC (to FX2NC-CNV-IF or FX3UC-1PS-5V) FX1N SERIES Manual FX1N SERIES HARDWARE MANUAL.
Can be single phase, dual phase 50kHz hardware counter high-speed input FX1N SERIES
High speed uniform output function with hardware comparison circuit.
In the dual phase count, 1, 2, and 4 multiplication modes can be set.
Can be licensed and reset by PLC or external input.
Differential output type encoder. Max input / output points: 16 points.
Supply voltage: 100 - 240VAC FX1N SERIES Manual FX1N SERIES HARDWARE MANUAL.
Input points: 8 points.
Output points: 8 points.
Output type: transistor.
Power consumption: 30VA.
Weight (kg):0.6.
Size (WxHxD) mm:130x90x87.
Note recording function, Component annotation can be recorded in the program register.
Online program editor, online change the program will not lose the working hours or stop production operation.
RUN/STOP switch, running on panel / stop switch easy to operate FX1N SERIES Manual FX1N SERIES HARDWARE MANUAL.
Remote maintenance, remote programming software can monitor, upload or uninstall programs and data via modem communications
Password protection, using a eight digit password to protect your program.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard.
Continuous scanning function, to define the operation cycle for the application of the continuous scan time.
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017). "MITSUBISHI inverter FR-F720P series.
Voltage level: three phase 200V.
Frequency converter capacity: 15KW.
When the inverter is running, the starting current and starting torque of the motor are how?
With the operation of the inverter, with the acceleration of the motor to improve the frequency and voltage,
The starting current is limited to 150% below the rated current (according to the different types of aircraft, 125%~200%).
It is based on the overall effect of three-phase waveform generation,
In order to approach the ideal circular rotating magnetic field in the air gap of the motor,
A generation phase modulation waveform control inscribesthe polygon to approach the circle way.
After practice, it has been improved, that is, the introduction of frequency compensation, can eliminate the error of speed control;
By feedback estimation of flux amplitude, eliminating the influence of stator resistance at low speed, the output voltage and current closed loop,
In order to improve the accuracy and stability of the dynamic.
But there are many control circuit, and no torque is introduced, so the system performance has not been improved.
Frequency converter is a power control device which uses the power of the power semiconductor device to change the power frequency to another frequency,
Can realize the asynchronous motor soft start, variable frequency speed regulation, improve the operation precision, change the power factor, over current / over voltage / overload protection and other functions.
The use of frequency converter motor is in order to speed, and reduce the starting current.
In order to produce a variable voltage and frequency,
The equipment to the power of the AC power conversion to DC (DC), the process is called rectification.
The direct current (DC) is transformed into alternating current (AC) and its scientific term is "inverter" (inverter).
General inverter is the DC power supply inverter for a certain fixed frequency and a certain voltage of the inverter.
For the inverter as the frequency adjustable, adjustable voltage inverter, we called the inverter.
Inverter output waveform is simulated sine wave,
Is mainly used in three-phase asynchronous motor speed control, and also called frequency governor.
For the variable frequency inverter, which is mainly used in the testing eequipment of instrument and meter,
To sort out the waveform, you can output the standard sine wave, called the inverter power supply FX1N SERIES Manual FX1N SERIES HARDWARE MANUAL.
The general inverter is 1520 times inverter price.
The main device called "inverter" because of the voltage or frequency of the inverter device ",
Therefore, the product itself is named "inverter", that is: inverter FX1N SERIES Manual FX1N SERIES HARDWARE MANUAL. "
Related products
MITSUBISHI
Old small A series expansion substrate
QA1S51B
MITSUBISHI Old small A series expansion substrate QA1S51B
1 slots no power supply used to install lar
MITSUBISHI
Old small A series expansion substrate
QA1S68B
MITSUBISHI Old small A series expansion substrate QA1S68B
8 slots requires 1 AnS series PLC power modu
MITSUBISHI
A mode Q series CPU
Q02HCPU-A
MITSUBISHI A mode Q series CPU Q02HCPU-A
Input / output points: 4096 points. Numer of