MITSUBISHI
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI FX1N-40MT-001 Manual FX1N-40MT-001 HARDWARE MANUAL

MITSUBISHI FX1N-40MT-001 Manual FX1N-40MT-001 HARDWARE MANUAL

Brand: MITSUBISHI
Product model: FX1N-40MT-001
Name: PLC
Sort: HARDWARE MANUAL
File language: English
File size: 2.00MB
Cable length: 0.5m.
RS-485 terminal unit conversion unit.
Applicable model: GT16. Input points: 4 points.
Weight: 0.02kg.
Function expansion board is used in the FX3SA, FX3S, FX3GA, FX3G, FX3GE on the small number of input and output extension of the product,
Can be built into PLC. Specifications: FX0N-30EC FX1N-40MT-001 Manual FX1N-40MT-001 HARDWARE MANUAL.
Cable extending unit.
Length 30CM. Axis of control: 1 FX1N-40MT-001
Applicable PLC:FX1N, FX2N, FX3U, FX2NC (to FX2NC-CNV-IF).
Applicable PLC:FX3UC (to FX2NC-CNV-IF or FX3UC-1PS-5V).
7 operating modules required for easy positioning control are provided.
Type of instruction, please refer to the list in front of you.
One can control a shaft.
FX3U, PLC FX2N can connect up to 8 units,
PLC FX2NC can connect up to 4 units,
PLC FX3UC can connect up to 7 units, so that it can control more than one independent axis FX1N-40MT-001 Manual FX1N-40MT-001 HARDWARE MANUAL.
Maximum can output 100kHz pulse train.
Positioning control through the control program. Input and output points: 40 points.
Power supply: DC24V.
Input points: 24 points.
Output points: 16 points.
Output form: transistor output (source).
Power consumption: 25W.
Weight: 0.7KG.
Outline dimension: 130x90x86mm FX1N-40MT-001 Manual FX1N-40MT-001 HARDWARE MANUAL.
FX3GE on the performance of the FX3GA increased analog input / output and Ethernet communication and other built-in features.
Applicable to a wide variety of applications.
Basic unit: 24/40 point.
Third generation standard model.
High flexibility.
Suitable for small scale control of high cost PLC.
Control points to 128 points, the use of CC-Link remote I/O can control the maximum 256 points.
A versatile PLC.
Built in CPU, power supply, input and output, analog input and output, Ethernet port, can be used immediately after the purchase.
High speed operation.
Basic instructions: 0.21 s/ instruction.
Application instruction: 0.5 s/ instruction.
Large capacity memory.
Built in program memory 32000 steps.
EEPROM memory cartridge with program transfer function. "MITSUBISHI inverter FR-F720P series.
Voltage level: three phase 200V.
Frequency converter capacity: 2.2KW.
When the inverter is running, the starting current and starting torque of the motor are how?
With the operation of the inverter, with the acceleration of the motor to improve the frequency and voltage,
The starting current is limited to 150% below the rated current (according to the different types of aircraft, 125%~200%).
It is based on the overall effect of three-phase waveform generation,
In order to approach the ideal circular rotating magnetic field in the air gap of the motor,
A generation phase modulation waveform control inscribesthe polygon to approach the circle way.
After practice, it has been improved, that is, the introduction of frequency compensation, can eliminate the error of speed control;
By feedback estimation of flux amplitude, eliminating the influence of stator resistance at low speed, the output voltage and current closed loop,
In order to improve the accuracy and stability of the dynamic.
But there are many control circuit, and no torque is introduced, so the system performance has not been improved.
Frequency converter is a power control device which uses the power of the power semiconductor device to change the power frequency to another frequency,
Can realize the asynchronous motor soft start, variable frequency speed regulation, improve the operation precision, change the power factor, over current / over voltage / overload protection and other functions.
The use of frequency converter motor is in order to speed, and reduce the starting current.
In order to produce a variable voltage and frequency,
The equipment to the power of the AC power conversion to DC (DC), the process is called rectification.
The direct current (DC) is transformed into alternating current (AC) and its scientific term is "inverter" (inverter).
General inverter is the DC power supply inverter for a certain fixed frequency and a certain voltage of the inverter.
For the inverter as the frequency adjustable, adjustable voltage inverter, we called the inverter.
Inverter output waveform is simulated sine wave,
Is mainly used in three-phase asynchronous motor speed control, and also called frequency governor.
For the variable frequency inverter, which is mainly used in the testing equippment of instrument and meter,
To sort out the waveform, you can output the standard sine wave, called the inverter power supply FX1N-40MT-001 Manual FX1N-40MT-001 HARDWARE MANUAL.
The general inverter is 1520 times inverter price.
The main device called "inverter" because of the voltage or frequency of the inverter device ",
Therefore, the product itself is named "inverter", that is: inverter FX1N-40MT-001 Manual FX1N-40MT-001 HARDWARE MANUAL. "
Related products
MITSUBISHI
PLC
FX1N-40MR-DS
MITSUBISHI PLC FX1N-40MR-DS
Max input / output points: 40 points. Power s
MITSUBISHI
PLC
FX2N-128MT-001
MITSUBISHI PLC FX2N-128MT-001
Max input / output points: 128 points. Power
MITSUBISHI
RS-485 expansion board
FX1N-485-BD
MITSUBISHI RS-485 expansion board FX1N-485-BD
Function extension oard for RS-485 communica
MITSUBISHI
PLC
FX1N-40MT-ESS/UL
MITSUBISHI PLC FX1N-40MT-ESS/UL
Max input / output points: 40 points. Supply