Output: 16 points.
Function: transistor output models (source type).
Corresponding models: FX3GA, FX3G, FX3GE, FX3GC, FX3U, FX3UC.
Can carry on the FX3GC, the FX3UC basic unit and the expansion module or the localization module the connector and the terminal station transformation,
Save the time of the input and output connection, realize the labor saving FX-4AD-TC Manual FX-4AD-TC USER'S GUIDE.
The use of built-in input and output components models,
Can receive AC100V input, or through the relay or the transistor to drive large capacity load
FX-4AD-TC Maximum frequency: 50kHz.
Input points: 1 points.
Output form: transistor 2 point output.
Weight: 0.13kg.
FX2NC-1HC can achieve high speed counting by 1 phase /2 phase 50kHz hardware counter FX-4AD-TC Manual FX-4AD-TC USER'S GUIDE.
Hardware comparator with high speed matching output function.
In the 2 phase count, can be set 1, 2, 4 frequency.
Can be achieved by PLC or external input to count the licensing / prohibition.
Can also be connected to the linear drive output type of the encoder.
FX2NC-1HC can only be connected to FX3UC. MITSUBISHI inverter series: FR-F840.
Voltage level: three phase 400V.
Power: 18.5kw.
SLD converter rated current: 38 FX-4AD-TC Manual FX-4AD-TC USER'S GUIDE. 0A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
2 times the power consumption of the wind turbine and pump and the speed of the 3 power consumption is proportional to the speed of the rotating speed.
Through the speed control of the frequency converter to adjust the air flow, can reduce the power consumption.
Give full play to the performance of the motor.
The excitation current is always adjusted to the best state, which can improve the efficiency of the motor.
Load torque is smaller, can further improve energy efficiency.
For example, when a general motor is used, the optimal excitation control mode in the 4% motor load torque is about 30% more than that of the V/F control. Power: 55kw.
Voltage: 200V.
There are 100% braking torque output in continuous regenerationn, which can correspond to the continuous regeneration operation of the pipeline control FX-4AD-TC Manual FX-4AD-TC USER'S GUIDE.
There is no need to install the braking unit for each frequency converter, which can reduce the comprehensive space annd reduce the comprehensive cost FX-4AD-TC Manual FX-4AD-TC USER'S GUIDE.
Renewable energy can be used for other frequency converter, excess energy back to the grid, to achieve energy saving.