Output points: 32 points.
Power supply: the basic unit to the expansion module to provide power.
Output form: transistor output (source).
Terminal type: connector type.
Weight: 0.2kg.
FX3GC, FX3UC can be directly connected to the input and output expansion equipment, to achieve a compact expansion.
Can choose 16 points, 32 points of the relay or transistor input and output models FR-F740P-11K-CHT Applied Manual FR-F740P-11K-CHT Instruction manual
FR-F740P-11K-CHT
FX2NC-16E_-T-DS for terminal units can be disassembled models. Power: 22kw.
Voltage: 200V.
The surge voltage of the motor can be suppressed when the 400V motor is driven by a frequency converter.
Motor suitable for 5.5 to 37kW. MITSUBISHI inverter FR-F740 series.
Voltage level: three phase 400V.
Frequency converter capacity: 22KW FR-F740P-11K-CHT Applied Manual FR-F740P-11K-CHT Instruction manual.
Frequency converter common frequency of a given way: the operator keyboard is given, the contact signal given, analog signal given, the pulse signal given and communication methods given, etc..
These frequencies have their advantages and disadvantages, and should be selected according to the actual needs.
Frequency converter is a power control device which uses the power of the power semiconductor device to change the power frequency to another frequency,
Can realize the asynchronous motor soft start, variable frequency speed regulation, improve the operation precision, change the power factor, over current / over voltage / overload protection and other functions FR-F740P-11K-CHT Applied Manual FR-F740P-11K-CHT Instruction manual. MITSUBISHI inverter series: FR-F842.
Voltage level: three phase 400V.
Power: 500kw.
SLD converter rated current: 1094A.
Structure and function: the rectification part is off type.
Type: CA.
Substrate coating: have.
Energy saving by high efficiency motor.
Reduce standby power consumption.
DC24V external power supply, the input MC signal can be stopped after the motor for the OFF, in the motor drive for the ON.
Standby power management can be carried out by means of frequency converter to realize the power consumption reduction of standby time.
According to the temperature of the inverter cooling fan, the operation of the inverter can be controlled FR-F740P-11K-CHT Applied Manual FR-F740P-11K-CHT Instruction manual.
According to the operating conditions of the inverter cooling fan output the correspondinng signal,
Therefore, the inverter and other built-in fan and inverter cooling fan synchronous operation FR-F740P-11K-CHT Applied Manual FR-F740P-11K-CHT Instruction manual.
Can reduce the power consumption in the stop.