Connecting cable for handheld RH GOT and PLC.
Cable length: 6 meters.
Application: RS-422 connection and RS-232C connection. Voltage level: three phase 400V.
Applicable motor capacity: 500kw.
Substrate coating: have.
Built in DC reactor.
The operating frequency of the fixed alternating current is converted to DC power FR-F540-0.75K to 55K(-EC) Manual FR-F540-0.75K to 55K(-EC) INSTRUCTION MANUAL. Length: 3m
FR-F540-0.75K to 55K(-EC)
Specification: D-sub 25 pin (male), D-sub 25 pin (male). Power: 3.7kw.
Purpose: high frequency braking resistor.
The use rate of the built-in regenerative brake of the transducer can be promoted.
When using the FR-ABR type brake resistor, the short circuit piece between the terminal PR-PX is removed. Does not remove the short circuit chip will lead to overheating of the brake resistor FR-F540-0.75K to 55K(-EC) Manual FR-F540-0.75K to 55K(-EC) INSTRUCTION MANUAL.
The utilization rate of the regenerative braking should be less than the allowable brake use rate in the above table.
With the operating frequency of the brake resistor to reach 300 degrees C or higher, it is necessary to take protective measures and cooling.
MYS type resistor can be used. But please pay attention to the allowable brake use rate.
Do not remove the terminal P/+ and P1 between the short circuit chip, in addition to connecting the DC reactor FR-F540-0.75K to 55K(-EC) Manual FR-F540-0.75K to 55K(-EC) INSTRUCTION MANUAL.
The installation of thermal relay, to avoid overheating and burn the braking resistor. MITSUBISHI inverter FR-F740 series.
Voltage level: three phase 400V.
Frequency converter capacity: 500KW.
The main circuit of the inverter can be divided into two categories in general: voltage type is the voltage source of the DC converter for AC inverter,
The filtering of the DC circuit is the capacitance; the current mode is the DC conversion of the current source to the AC inverter,
The DC loop filter is the inductor.
Why is the frequency of the inverter voltage proportional to the change?
The electromagnetic torque of any motor is thhe result of the interaction between the current and the magnetic flux, the current is not allowed to exceed the rated value, otherwise it will cause the heating of the mmotor FR-F540-0 FR-F540-0.75K to 55K(-EC) Manual FR-F540-0.75K to 55K(-EC) INSTRUCTION MANUAL. 75K to 55K(-EC) Manual FR-F540-0.75K to 55K(-EC) INSTRUCTION MANUAL.
Therefore, if the magnetic flux decreases, the electromagnetic torque will decrease, which leads to the reduction of the load carrying capacity.