MITSUBISHI inverter FR-A740 series.
Voltage level: 3 phase 400V.
Frequency converter capacity: 0.4KW.
FR-A700 converter products are suitable for all kinds of high load requirements of the equipment.
Such as lifting, lift, printing and dyeing, printing and dyeing, material coiling and other general occasions FR-E720S-0.4K Applied Manual FR-E720S-0.4K Instruction manual.
High level driving performance
FR-E720S-0.4K
Unique sensorless vector control mode,
A wide variety of mechanical equipment can be operated at high precision in the super low speed region without the need of the encoder.
With torque control mode,
And in the speed control mode can use the torque limit function.
With vector control function (with encoder),
Frequency converter can achieve position control and fast response, high precision speed control (zero speed control, servo lock, etc FR-E720S-0.4K Applied Manual FR-E720S-0.4K Instruction manual. ) and torque control. Max input / output points: 10 points.
Supply voltage: 100 - 240VAC.
Input points: 6 points.
Output points: 4 points.
Output type: Transistor (source).
Power consumption (W): 6.
Weight (kg):0.22.
Size (WxHxD) mm:60x90x49.
Host has 10 points (6I/4O), 14 points (8I/6O), 20 points (12I/8O), 30 points (16I/14O) of 4 types FR-E720S-0.4K Applied Manual FR-E720S-0.4K Instruction manual.
This type of PLC is mainly used in all of the digital input, digital output control point of the device.
Can be directly connected to the 220V city power, built-in 8K step EEPROM memory, no battery, easy to maintain.
The series transistor output (MT) of the PLC, can be output 2 100KHz pulse, direct drive servo or stepper motor.
The series PLC can not be brought with the expansion module, but can be installed by the BD board to extend a small amount of I/O.
The series 1N through the installation of BD series PLC board, can achieve RS232, RS485, RS422 communication. Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.MITSUBISHI inverter series: FR-F840.
Voltage level: three phase 400V.
Power: 55kw.
SLD converter rated current: 116A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
The motor efficiency is not changed in the previous optimal excitation control,
At the same time, the newly developed advanced optimal excitation control can obtain larger torque at startup.
No need to adjust the parameters (plus deceleration time or torque, etc.), in a short time to speed up to a certain speed,
Can be carried out to maximize the efficiency of energy-saving drive motor.
The automatic tuning function of the loop constant of the motor is not consistent with the constant of the motor, the motor of other manufacturers, and the length of wiring is too long,
Optimum operating characteristic drive motor.
In the state of the sensor can noot only drive the high efficiency and energy saving motor and PM motor (MM-EFS), but also can drive other companies induction motor and PM motor (permanent magnet synchronous motor) FR-E720S-0.4K Applied Manual FR-E720S-0.4K Instruction manual.
Othher manufacturers of induction motors, can also be automatically tuned to achieve the best excitation control, thus expanding the use of energy saving FR-E720S-0.4K Applied Manual FR-E720S-0.4K Instruction manual.