Max input / output points: 80 points.
Power supply voltage: 24VDC.
Input points: 40 points.
Output points: 40 points.
Output type: Transistor (source).
Power consumption: 40W.
Weight (kg):1.2.
Size (WxHxD) mm:285x90x87.
Developed a range of special function modules to meet the needs of different - analog I/O, high speed counter FR-E5NP Manual FR-E5NP INSTRUCTION MANUAL.
Positioning control to achieve the 16 axis, the pulse train output or for the J and K type thermocouple or Pt sensor developed the temperature module
FR-E5NP
A total of 8 special function modules can be configured for each FX2n main unit.
Note recording function, Component annotation can be recorded in the program register.
Online program editor, online change the program will not lose the working hours or stop production operation FR-E5NP Manual FR-E5NP INSTRUCTION MANUAL.
RUN/STOP switch, running on panel / stop switch easy to operate.
Remote maintenance, remote programming software can monitor, upload or uninstall programs and data via modem communications
Password protection, using a eight digit password to protect your program.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard FR-E5NP Manual FR-E5NP INSTRUCTION MANUAL.
Continuous scanning function, to define the operation cycle for the application of the continuous scan time.
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017). Auxiliary parts for FX3GC and FX3UC. "MITSUBISHI inverter series: FR-A820.
Voltage level: three phase 200V.
Power: 75kw.
SLD converter rated current: 380A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
Parameters can be selected by 4 different rated current and different overload rating (SLD (ultra light load) rated, LD (light load) rating, ND (general load) rating, HD (weight).
Type load) for selection.
You can choose the most suitable frequency converter for use; and by selecting a transducer with a SLD or LD rated level,
Be able to reduce the size of the device (compared with the FR-A700 series, too reduce the volume of equipment) FR-E5NP Manual FR-E5NP INSTRUCTION MANUAL.
For applications that require high torque at low speeds, the HD rating is the most suitable.
The controller is used to control and monitor the frequency converter through the network FR-E5NP Manual FR-E5NP INSTRUCTION MANUAL.
Standard corresponding RS-485 communication (MITSUBISHI converter protocol, Modbus-RTU protocol) data transmission speed up to 115200bps.