MITSUBISHI
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI FR-A820-30K-1 PLC FUNCTION Manual FR-A820-30K-1 Programming Manual

MITSUBISHI FR-A820-30K-1 PLC FUNCTION Manual FR-A820-30K-1 Programming Manual

Brand: MITSUBISHI
Product model: FR-A820-30K-1
Name: INVERTER
Sort: Programming Manual (PLC FUNCTION)
File language: English
File size: 8.95MB
Max input / output points: 30 points.
Power supply voltage: DC24V.
Input points: 16 points.
Output points: 14 points.
Output type: Transistor (source).
Power consumption (W): 21.
Weight (kg):0.45.
Size (WxHxD) mm:100x90x75.
Positioning and pulse output functions: a PLC cell can output 2 point 100KHz pulses at the same time FR-A820-30K-1 PLC FUNCTION Manual FR-A820-30K-1 Programming Manual.
PLC is equipped with 7 special positioning instructions,
Including zero return, absolute or relative address expression and special pulse output control FR-A820-30K-1
Host has 10 points (6I/4O), 14 points (8I/6O), 20 points (12I/8O), 30 points (16I/14O) of 4 types.
This type of PLC is mainly used in all of the digital input, digital output control point of the device.
Can be directly connected to the 220V city power, built-in 8K step EEPROM memory, no battery, easy to maintain FR-A820-30K-1 PLC FUNCTION Manual FR-A820-30K-1 Programming Manual.
The series transistor output (MT) of the PLC, can be output 2 100KHz pulse, direct drive servo or stepper motor.
The series PLC can not be brought with the expansion module, but can be installed by the BD board to extend a small amount of I/O.
The series 1N through the installation of BD series PLC board, can achieve RS232, RS485, RS422 communication FR-A820-30K-1 PLC FUNCTION Manual FR-A820-30K-1 Programming Manual. LINK MELSEC-I/O master module.
DC5V consumption current: 200mA.
High speed counter equipped with 6 to 8 channels.
FX series of all models are standard with a high-speed counter.
Through a simple procedure to achieve high speed control.
Through the CC-Link and a variety of machine communications, the province of wiring.
Using CC-Link to control a variety of FA machines.
FX3G (*) /FX3U (C) series can be expanded by CC-Link control points.
Data communication with various machines using Ethernet.
FX3 series through Ethernet expansion device,
The monitoring and maintenance of equipment can be easily carried out in a place far from the scene.
Various machine communication with MODBUS protocol
Special adapter for MODBUS communications,
FX3 series can be used as a master or slave station with a variety of MODBUS protocol machine communication. Max input / output points: 80 points.
Power supply voltage: 24VDC.
Input points: 40 points.
Output points: 40 points.
Output type: transistor.
Power consumption: 40W.
Weight (kg):1.2.
Size (WxHxD) mm:285x90x87.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard.
Continuous scanning function, to define the operation cycle for the application of the continuous scan time.
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017).
Note recording function, Component annotation can be recorded in the program register.
Since the FX2n series have the following features: the maximum range of inclusive of the standard features, program execution faster, the full complement of communication function, suitable for different countries in the world, and the power to meet a large number of special function modules of individual needs,
It can provide maximum flexibility and control capability for your factory automation applications.
Control 16~256 point.
Built in 8K capacity of the RAM memory, the maximum can be extended to 16K.
CPU arithmetic processing speed of 0.08 S/ basic instructions.
On the right side of the FX2N series can be connected to the input and outtput expansion modules and special function modules FR-A820-30K-1 PLC FUNCTION Manual FR-A820-30K-1 Programming Manual.
The basic unit is built in the 2 axis independent maximum 20kHz positioning function (transistor output type).
Quick disconnect the terminal block, which adopts excellent maintainability to quickly disconnect the terminal blocks, even if the cable is then replaced by the cable FR-A820-30K-1 PLC FUNCTION Manual FR-A820-30K-1 Programming Manual.