MITSUBISHI inverter FR-F720 series.
Voltage level: three phase 200V.
Frequency converter capacity: 37KW.
When the ring is opened, the frequency converter is provided with a load of the motor when the motor is operated with a load at a given frequency,
The range of the motor speed in the rated slip ratio (1%~5%) changes FR-A720-00030 to 03460-NA Manual FR-A720-00030 to 03460-NA INSTRUCTION MANUAL.
For the requirements of relatively high precision, even if the load changes are also required to operate at a given speed of the occasion,
Inverter with PG feedback function can be used (selection)
FR-A720-00030 to 03460-NA
If the given acceleration time is too short, the output frequency of the inverter is far more than the change of the speed (electric angular frequency),
Converter will be due to flow over the current trip, the operation stopped, which is called stall FR-A720-00030 to 03460-NA Manual FR-A720-00030 to 03460-NA INSTRUCTION MANUAL. Max input / output points: 64 points.
Supply voltage: 100 - 240VAC.
Input points: 32 points.
Output points: 32 points.
Output type: Transistor (source).
Power consumption: 60VA.
Weight (kg):1.0.
Size (WxHxD) mm:220x90x87.
Developed a range of special function modules to meet the needs of different - analog I/O, high speed counter FR-A720-00030 to 03460-NA Manual FR-A720-00030 to 03460-NA INSTRUCTION MANUAL.
Positioning control to achieve the 16 axis, the pulse train output or for the J and K type thermocouple or Pt sensor developed the temperature module.
A total of 8 special function modules can be configured for each FX2n main unit.
Note recording function, Component annotation can be recorded in the program register.
Online program editor, online change the program will not lose the working hours or stop production operation.
RUN/STOP switch, running on panel / stop switch easy to operate.
Remote maintenance, remote programming software can monitor, upload or uninstall programs and data via modem communications
Password protection, using a eight digit password to protect your program.
Clockk function and hour meter function, all of the PLC FX2N has a real-time clock standard FR-A720-00030 to 03460-NA Manual FR-A720-00030 to 03460-NA INSTRUCTION MANUAL.
Continuous scanning function, to define the operation cycle for the application off the continuous scan time FR-A720-00030 to 03460-NA Manual FR-A720-00030 to 03460-NA INSTRUCTION MANUAL.
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017).