696此ID下载地址不存在3--/downloadfile/438manual-66790.pdf MITSUBISHI FR-A520-0.4K to 55K-NA Manual FR-A520-0.4K to 55K-NA INSTRUCTION MANUAL - MITSUBISHI
MITSUBISHI
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI FR-A520-0.4K to 55K-NA Manual FR-A520-0.4K to 55K-NA INSTRUCTION MANUAL

MITSUBISHI FR-A520-0.4K to 55K-NA Manual FR-A520-0.4K to 55K-NA INSTRUCTION MANUAL

Brand: MITSUBISHI
Product model: FR-A520-0.4K to 55K-NA
Name: TRANSISTORIZED INVERTER
Sort: INSTRUCTION MANUAL
File language: English
File size: 0.00MB
MITSUBISHI inverter FR-A720 series.
Voltage level: 3 phase 200V.
Frequency converter capacity: 1.5KW.
Inverter output for the PWM wave, containing more harmonic.
Frequency conversion power sensor through the input voltage and current signals to exchange sampling,
Sampling value through cable, optical fiber and other transmission systems and digital input frequency conversion power analyzer,
The sampling value of the voltage and current is calculated by the digital input frequency conversion power analyzer,
It can obtain the parameters such as voltage effective value, current effective value, fundamental wave voltage, fundamental current, harmonic voltage, harmonic current, active power, fundamental wave power and harmonic power FR-A520-0 FR-A520-0.4K to 55K-NA4K to 55K-NA Manual FR-A520-0 FR-A520-0.4K to 55K-NA Manual FR-A520-0.4K to 55K-NA INSTRUCTION MANUAL. 4K to 55K-NA INSTRUCTION MANUAL. Max input / output points: 32 points.
Supply voltage: 100 - 240VAC.
Input points: 16 points.
Output points: 16 points.
Output type: Transistor (sinktype).
Power consumption: 40VA.
Weight (kg):0.65.
Size (WxHxD) mm:150x90x87.
Developed a range of special function modules to meet the needs of different - analog I/O, high speed counter.
Positioning control to achieve the 16 axis, the pulse train output or for the J and K type thermocouple or Pt sensor developed the temperature module FR-A520-0.4K to 55K-NA Manual FR-A520-0.4K to 55K-NA INSTRUCTION MANUAL.
A total of 8 special function modules can be configured for each FX2n main unit.
Note recording function, Component annotation can be recorded in the program register.
Online program editor, online change the program will not lose the working hours or stop production operation.
RUN/STOP switch, running on panel / stop switch easy to operate.
Remote maintenance, remote programming software can monitor, upload or uninstall programs and data via modem communications
Password protection, using a eight digit password to protect your program. FR-A520-0.4K to 55K-NA Manual FR-A520-0.4K to 55K-NA INSTRUCTION MANUAL.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard.
Continuous scanning function, to define the operation cycle for the application off the continuous scan time FR-A520-0.4K to 55K-NA Manual FR-A520-0.4K to 55K-NA INSTRUCTION MANUAL.
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017).
Related products