File size: 0.22MB
Max input / output points: 10 points.
Power supply voltage: DC24V.
Input points: 6 points.
Output points: 4 points.
Output type: relay.
Power consumption (W): 19.
Weight (kg):0.3.
Size (WxHxD) mm:60x90x75.
Positioning and pulse output functions: a PLC cell can output 2 point 100KHz pulses at the same time F940WGOT-TWD-E Manual F940WGOT-TWD-E Installation Manual.
PLC is equipped with 7 special positioning instructions,
Including zero return, absolute or relative address expression and special pulse output control F940WGOT-TWD-E
Host has 10 points (6I/4O), 14 points (8I/6O), 20 points (12I/8O), 30 points (16I/14O) of 4 types.
This type of PLC is mainly used in all of the digital input, digital output control point of the device.
Can be directly connected to the 220V city power, built-in 8K step EEPROM memory, no battery, easy to maintain F940WGOT-TWD-E Manual F940WGOT-TWD-E Installation Manual.
The series transistor output (MT) of the PLC, can be output 2 100KHz pulse, direct drive servo or stepper motor.
The series PLC can not be brought with the expansion module, but can be installed by the BD board to extend a small amount of I/O.
The series 1N through the installation of BD series PLC board, can achieve RS232, RS485, RS422 communication F940WGOT-TWD-E Manual F940WGOT-TWD-E Installation Manual. Power: 400kw.
Voltage: 400V.
The power factor of the input power factor is up to 0.99 and above (100% load).
Can be connected to multiple inverters, to achieve a common DC bus mode.
Equipped with standard power retrogradation function. Length: 5 meters.
Cable manufacturing specifications.
When there is no connection options, according to the table under the cable.
Using a parallel connection or a large size cable for connection between the terminal PG" and "SD" and the motor end encoder. "MITSUBISHI inverter series: FR-A820.
Voltage level: three phase 200V.
Power: 11kw.
SLD converter rated current: 63A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
Parameters can be selected by 4 different rated current and different overload rating (SLD (ultra light load) rated, LD (light load) rating, ND (general load) rating, HD (weight).
Type load) for selection.
You can choose the most suitable frequency converter for use; and by selecting a transducer with a SLD or LD rated level,
Be able to reduce the size of the device (compared with the FR-A700 series, to reduce the voluume of equipment) F940WGOT-TWD-E Manual F940WGOT-TWD-E Installation Manual.
For applications that require high torque at low speeds, the HD rating is the most suitable.
The controller is used to control and monitor the frequency converter through the network F940WGOT-TWD-E Manual F940WGOT-TWD-E Installation Manual.
Standard corresponding RS-485 communication (MITSUBISHI converter protocol, Modbus-RTU protocol) data transmission speed up to 115200bps.
Related products
MITSUBISHI
5.7 Inch Touch Screen
F940WGOT-LWD
MITSUBISHI 5.7 Inch Touch Screen F940WGOT-LWD
Series Name: F940GOT. System screen display l
MITSUBISHI
5.7 Inch Touch Screen
F940WGOT-LWD-E
MITSUBISHI 5.7 Inch Touch Screen F940WGOT-LWD-E
Series Name: F940GOT. System screen display l
MITSUBISHI
6.7 Inch Touch Screen
F940WGOT-TWD-E
MITSUBISHI 6.7 Inch Touch Screen F940WGOT-TWD-E
Series Name: F940WGOT. System screen display
MITSUBISHI
5.7 Inch Touch Screen
F940WGOT-LWD-C
MITSUBISHI 5.7 Inch Touch Screen F940WGOT-LWD-C
Series Name: F940GOT. System screen display l