135此ID下载地址不存在3--/downloadfile/152dsfas.pdf MITSUBISHI F1 series HIGH FUNCTION VERSION Manual F1 series Programming Manual - MITSUBISHI
MITSUBISHI
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI F1 series HIGH FUNCTION VERSION Manual F1 series Programming Manual

MITSUBISHI F1 series HIGH FUNCTION VERSION Manual F1 series Programming Manual

Brand: MITSUBISHI
Product model: F1 series
Name: PLC
Sort: Programming Manual (HIGH FUNCTION VERSION)
File language: English
File size: 0.00MB
Input signal power: 40mA. DC24V
Axis of control: 1.
Output frequency: Max 200kHz.
Weight: 0.2kg.
FX3U-1PG is a pulse output module of the maximum output 200kHz pulse train.
7 operation modes needed to take the simple position control.
The speed and the target address can be changed in the positioning operation according to the operation of the project,
Support near S shape plus deceleration F1 series HIGH FUNCTION VERSION Manual F1 series Programming Manual F1 series High speed positioning can be carried out smoothly.
Up to 8 units can be connected to FX3U or FX3UC.
Connecting FX3UC requires FX2NC-CNV-IF or FX3UC-IPS-5V. MITSUBISHI inverter series: FR-F840.
Voltage level: three phase 400V.
Power: 110kw.
SLD converter rated current: 260A.
Structure and function: Standard model F1 series HIGH FUNCTION VERSION Manual F1 series Programming Manual.
Type: CA.
Substrate coating: have.
The motor efficiency is not changed in the previous optimal excitation control,
At the same time, the newly developed advanced optimal excitation control can obtain larger torque at startup.
No need to adjust the parameters (plus deceleration time or torque, etc.), in a short time to speed up to a certain speed,
Can be carried out to maximize the efficiency of energy-saving drive motor F1 series HIGH FUNCTION VERSION Manual F1 series Programming Manual.
The automatic tuning function of the loop constant of the motor is not consistent with the constant of the motor, the motor of other manufacturers, and the length of wiring is too long,
Optimum operating characteristic drive motor.
In the state of the sensor can not only drive the high efficiency and energy saving motor and PM motor (MM-EFS), but also can drive other companies induction motor and PM motor (permanent magnet synchronous motor).
Other manufacturers of induction motors, can also be automatically tuned to achieve the best excitation control, thus expanding the use of energy saving. MITSUBISHI inverter series: FR-A820.
Voltage level: three phase 200V.
Power: 5.5kw.
SLD converter rated current: 34A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
Parameters can be selected by 4 different rated current and different overload rating (SLD (ultra light load) rated, LD (light load) rating, ND (general load) rating, HD (weight).
Type load) for selection.
You can choose the most suitable frequency converter for use; and by selecting a transducer with a SLD or LD rated level,
Be able to reduce the size of the device (compared with the FR-A700 series, to reduce the volume of equuipment) F1 series HIGH FUNCTION VERSION Manual F1 series Programming Manual.
For applications that require high torque at low speeds, the HD rating is the most suitable.
The controller is used to control and monitor the frequency converter through the network F1 series HIGH FUNCTION VERSION Manual F1 series Programming Manual.
Standard corresponding RS-485 communication (MITSUBISHI converter protocol, Modbus-RTU protocol) data transmission speed up to 115200bps.