MITSUBISHI CL1XY8-DR1B2 Manual CL1XY8-DR1B2 User's Manual

Brand: MITSUBISHI
Product model: CL1XY8-DR1B2
Name: CC-Link/LT Remote I/O Module
Sort: User's Manual
File language: English
File size: 0.23MB
Input voltage rating: AC100/120/230/240V
External connection mode: module power supply: Terminal 3 pin (M3 screw), communication line / module power supply unit.
Dedicated power supply for CC-LINK/LT system with built-in 2A power supply. Input type: DC input, positive common end.
Input points: 16 points CL1XY8-DR1B2 Manual CL1XY8-DR1B2 User's Manual.
Input response time: 0.5ms below /1.5ms.
Rated input voltage / current: DC24V/4mA CL1XY8-DR1B2
External connection: 3 wire.
Sensor connection type.
Minimum size of industry.
When installing the module can choose to use the DIN guide rail or screw mounting.
3 wire sensor input. Voltage and current output module.
Number of channels: 2 channels.
Occupied station number: 16 point pattern occupies 4 stations CL1XY8-DR1B2 Manual CL1XY8-DR1B2 User's Manual.
Screw terminal table type.
Input output points can be saved by using different input and output points based on the final channel that allows the conversion.
Special flat cable directly mounted to the module. No introductionOutput type: transistor output, source.
Output points: 16 points.
OFF leakage current: 0.1mA.
Output protection function.
Rated load voltage / current: DC12V/DC24V/0.1A.
External connection: 1 wire CL1XY8-DR1B2 Manual CL1XY8-DR1B2 User's Manual.
MIL connector type.
Minimum size of industry.
Relay terminal, terminal station conversion module and electromagnetic valve, etc. are connected to a simple MIL connector.
Simply remove the connector can be replaced with a simple module.
Additional module power supply, I/O power sharing.
No additional I/O power supply, you can reduce the cost and set space. Input type: DC input, positive public end / negative public end.
Input points: 2 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/4mA.
Output form: relay output.
Output points: 2 points.
OFF leakage current: -.
Output protection function: No.
Rated load voltage / current: DC30V/AC250V/2A.
External connnection: 2 line /2 line type CL1XY8-DR1B2 Manual CL1XY8-DR1B2 User's Manual.
Screw terminal table type.
Minimum size of industry.
The connection object at a glance with terminal cover plate.
Input module for public end of positive pole and negativve pole CL1XY8-DR1B2 Manual CL1XY8-DR1B2 User's Manual.
Terminal table structure capable of connecting with 2 wire type sensor and load in the same condition.
Can be installed along the 6 direction.