MITSUBISHI
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI AY40 Manual AY40 User's Manual

MITSUBISHI AY40 Manual AY40 User's Manual

Brand: MITSUBISHI
Product model: AY40
Name: I/O Module
Sort: User's Manual
File language: English
File size: 3.29MB
Write adapter for EPROM 28 pinOutput points: 64 points.
Voltage: DC12/24V.
OFF leakage current: 0.1mA.
Output type: transistor output (type sink).
Response time: 2ms.
32 points / a common end.
40 pin connector.
With circuit breaker protection function.
With the surge absorber.
Each scanning process. Focus on the input signal sampling AY40 Manual AY40 User's Manual. Focus on the output signal to refresh AY40
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program AY40 Manual AY40 User's Manual.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive AY40 Manual AY40 User's Manual.
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference. Therefore PLC selection,
Under the premise of meeting the control requirements,
Should consider the best performance to price ratio, a reasonable choice of PLC.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program to do the compiler to compile the process of interpretation.
Read only memory. Manufacturers use, content can not be changed, power does not disappear. Input type: DC input, positive public end / negative public end.
Input points: 16 points.
Enter the response time: 10ms the following.
Rated input voltage / current: DC24V/5mA.
Output form: transistor output, leakage type AY40 Manual AY40 User's Manual.
Output points: 16 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC24V/DC24V/0.5A.
External connection: 1 line /1 line type.
A2C shape terminal.
Type of input and output terminal AY40 Manual AY40 User's Manual.
Shape and A2C input and output modules are identical (same mounting dimensions),
Machining and installing holes are not required.
Related products
MITSUBISHI
Transistor output module
AY40P
MITSUBISHI Transistor output module AY40P
Output points: 16 points. Voltage: DC12/24V.
MITSUBISHI
Bidirectional thyristor output module
AY61CE
MITSUBISHI Bidirectional thyristor output module AY61CE
Output points: 32 points. Voltage: DC5/12/24V
MITSUBISHI
Bidirectional thyristor output module
AY23
MITSUBISHI Bidirectional thyristor output module AY23
Output points: 32 points. Voltage: AC100 24
MITSUBISHI
Transistor output module
AY41P
MITSUBISHI Transistor output module AY41P
Output points: 32 points. Voltage: DC12/24V.