288此ID下载地址不存在3--/downloadfile/259-MELSEC-A-series-programmable-controllers(UL-standard-approved-equipment)-f.pdf MITSUBISHI AY10A-UL Manual AY10A-UL User's Manual - MITSUBISHI
MITSUBISHI
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI AY10A-UL Manual AY10A-UL User's Manual

MITSUBISHI AY10A-UL Manual AY10A-UL User's Manual

Brand: MITSUBISHI
Product model: AY10A-UL
Name: PLC
Sort: User's Manual
File language: English
File size: 0.00MB
Two slots in one side.
Power supply unit.
Q4AR duplex system.
Switch volume control is designed to,
According to the current input combination of the switch quantity and the history of the input sequence,
So that PLC generates the corresponding switching output,
In order to make the system work in a certain order AY10A-UL Manual AY10A-UL User's Manual.
So, sometimes also known as the order control AY10A-UL
And sequential control is divided into manual, semi-automatic or automatic.
And the control principle is decentralized, centralized and hybrid control three.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read AY10A-UL Manual AY10A-UL User's Manual.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions AY10A-UL Manual AY10A-UL User's Manual.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program to do the compiler to compile the process of interpretation.
Read only memory. Manufacturers use, content can not be changed, power does not disappear. JEMANET (OPCN-1) interface unit from the station.
The response time of PLC is the interval between the time of the change of the external output signal of the PLC and the time of the change of the external output signal which is controlled by it,
Lag time, this is the time constant of the input circuit,
The time constant of the output circuit, the arrangement of the user statement and the use of the instruction,
The cycle scan mode of PLC and the way of PLC to refresh the I/O and so on.
This phenomenon is called the I/O delaay time effect AY10A-UL Manual AY10A-UL User's Manual.
Input status and input information input from the input interface,
CPU will be stored in the working data memory or in the input image register.
And then combine the data and the program with CCPU AY10A-UL Manual AY10A-UL User's Manual.
The result is stored in the output image register or the working data memory,
And then output to the output interface, control the external drive.
Related products
MITSUBISHI
Relay output module
AY10
MITSUBISHI Relay output module AY10
Output points: 16 points. Voltage: DC24V/AC24
MITSUBISHI
Relay output module
AY10A
MITSUBISHI Relay output module AY10A
Output points: 16 points. Voltage: DC24V/AC24