MITSUBISHI
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI AX41-S1 Manual AX41-S1 User's Manual

MITSUBISHI AX41-S1 Manual AX41-S1 User's Manual

Brand: MITSUBISHI
Product model: AX41-S1
Name: I/O Module
Sort: User's Manual
File language: English
File size: 3.29MB
Input type: DC input, positive public end / negative public end.
Input points: 16 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/7mA.
External connection: 1 wire.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup AX41-S1 Manual AX41-S1 User's Manual.
Finger protection through the upper part of the terminal,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool AX41-S1 For A6TBXE/A6TBY36E/A6TBX54E/A6TBY54E/A6TBX70E (common cathode; source) long 5m.Output points: 32 points.
Voltage: DC12/24V.
OFF leakage current: 0 AX41-S1 Manual AX41-S1 User's Manual. 1mA.
Output type: transistor output (type sink).
Response time: 2ms.
32 points / a common end.
38 point terminal station.
With the surge absorber.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read AX41-S1 Manual AX41-S1 User's Manual.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive.
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference. Therefore PLC selection,
Under the premise of meeting the control requirements,
Shouldd consider the best performance to price ratio, a reasonable choice of PLC AX41-S1 Manual AX41-S1 User's Manual.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program tto do the compiler to compile the process of interpretation AX41-S1 Manual AX41-S1 User's Manual.
Read only memory. Manufacturers use, content can not be changed, power does not disappear.
Related products
MITSUBISHI
Moving CPU unit
A73CPUR21-S1
MITSUBISHI Moving CPU unit A73CPUR21-S1
Multi axis positioning controller. Coaxial da
MITSUBISHI
floor
A32B-S1
MITSUBISHI floor A32B-S1
2 slots. Can e installed in the power supply
MITSUBISHI
CPU unit
A2NCPUP21-S1
MITSUBISHI CPU unit A2NCPUP21-S1
Input and output points: 1024 points. Input /
MITSUBISHI
Extended substrate
A1S58B-S1
MITSUBISHI Extended substrate A1S58B-S1
I/O slots: 8 slots. Can you install the power