MITSUBISHI
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI AX21 Manual AX21 User's Manual

MITSUBISHI AX21 Manual AX21 User's Manual

Brand: MITSUBISHI
Product model: AX21
Name: I/O Module
Sort: User's Manual
File language: English
File size: 3.29MB
Bus connection.
Program 1 channel connection.
MITSUBISHI PLC detection, fault diagnosis and display and other procedures.
These procedures are relatively independent, generally in the basic completion of the program design and then add.
MITSUBISHI PLC protection and chain procedures.
Protection and chain is an indispensable part of the program, must be carefully considered AX21 Manual AX21 User's Manual AX21
It can avoid the control logic confusion caused by illegal operations. Screw, 2 piece type terminal.
Voltage / current output module.
Number of channels: 2 channels.
Number of stations: 2 stops.
Station type: remote equipment station.
High speed data transfer of up to 10Mbps;
The development of CC-LINK is not only to meet the control of high speed remote I/O,
But also to meet the high speed of the field of information control AX21 Manual AX21 User's Manual.
In order to achieve this goal, the transmission speed of CC-LINK is compared with that of the previous live network system to add 40 to 10Mbps.
Such a high speed can not affect the speed of the machine control while allowing a large number of data communication. Extension cable.
Length: 1000mm AX21 Manual AX21 User's Manual. Analog channel: 12 channels.
Input / output (resolution): 0 ~ 4000.
Conversion speed: 100ms/12 channel.
Analog module installation.
Power supply: DC24V.
According to the control requirements of the system, using the appropriate design method to design MITSUBISHI PLC program.
Procedures to meet the requirements of system control as the main line,
Write one by one to achieve the control function or the sub task of the program,
Gradually improve the functions specified by the system.
MITSUBISHI PLC detection, fault diagnosis and display and other procedures.
These procedures are relatively independent, generally in the basic completion of the program design and then add.
Hardware simulation method is to use a number of hardware equipment to simulate the generation of the signal,
The signals are connected to the input end of the PLC system in a hard wired way, and the timelinesss is strong AX21 Manual AX21 User's Manual.
Software simulation method is in the MITSUBISHI PLC in the preparation of a set of simulation program,
The simulation provides the field signal, which is simple and easy to operate, but it is not easy too guarantee the timeliness AX21 Manual AX21 User's Manual.
Simulation of the process of debugging, debugging method can be used to segment, and the monitoring function of programmer.
Related products
MITSUBISHI
CPU unit
A1NCPUP21
MITSUBISHI CPU unit A1NCPUP21
Input and output points: 256 points. Input /
MITSUBISHI
Input module
AX41-S1
MITSUBISHI Input module AX41-S1
Input points: 32 points. Voltage: DC12/24V. C
MITSUBISHI
Medium inertia small capacity servo motor
HG-SR121
MITSUBISHI Medium inertia small capacity servo motor HG-SR121
Servo motor series: medium inertia, small cap
MITSUBISHI
DC input / relay output module
AX40Y10C
MITSUBISHI DC input / relay output module AX40Y10C
Input points: 16 points. Input voltage and cu