MITSUBISHI AX10-UL Manual AX10-UL User's Manual

Brand: MITSUBISHI
Product model: AX10-UL
Name: PLC
Sort: User's Manual
File language: English
File size: 0.41MB
Position detection axis number: 1 axis.
Resolution: 4096 * 32 ~ 409.6 * 320 rotation (multi turn), 0.0039062mm/256mm ~ 0.015625mm/1024mm (linear type).
Number of output channels: 16 channels.
When communicating in the PLC network of MITSUBISHI,
There is no sense of difference and discontinuity in the network,
Can carry on the remote monitoring, modification, debugging and other work of data communication and program,
Without taking into account the level and type of network AX10-UL Manual AX10-UL User's Manual AX10-UL
MELSECNET/H and CC-Link use the way of loop communication,
Periodically automatically send and receive messages,
Does not require specialized data communication procedures,
Simple parameters can be set.
MELSECNET/H and CC-Link are used to transmit and receive the broadcast mode,
This can be done on the network data sharing AX10-UL Manual AX10-UL User's Manual.
For the use of Ethernet, MELSECNET/H, CC-Link network,
Can set the network parameters and various functions, simple and convenient in the Developer GX software screen. Input points: 32 points.
Voltage: AC200 ~ 240V.
Current: 12mA.
Response time: 25ms.
32 points / a common end.
38 point terminal station AX10-UL Manual AX10-UL User's Manual.
CE certification.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program to do the compiler to compile the process of interpretation.
Read only memory. Manufacturers use, content can not be changed, power does not disappear.
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive.
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference. Therefore PLC selection,
Under the premise of meeting the control requirements,
Should consider the best performance to price ratio, a reasonable choice of PLC.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image registerr are changed with the change of the execution of the program AX10-UL Manual AX10-UL User's Manual.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to thhe adoption of centralized sampling AX10-UL Manual AX10-UL User's Manual.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
Related products
MITSUBISHI
Input module
AX11
MITSUBISHI Input module AX11
Input points: 32 points. Voltage: AC100 120
MITSUBISHI
Input module
AX11C
MITSUBISHI Input module AX11C
Input points: 32 points. Input voltage: AC100
MITSUBISHI
AC input / relay output module
AX10Y10C
MITSUBISHI AC input / relay output module AX10Y10C
Input points: 16 points. Input voltage and cu
MITSUBISHI
AC input / silicon controlled output module
AX10Y22C
MITSUBISHI AC input / silicon controlled output module AX10Y22C
Input points: 16 points. Input voltage and cu