MITSUBISHI
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI AJ35TJ-8S1 Manual AJ35TJ-8S1 User's Manual

MITSUBISHI AJ35TJ-8S1 Manual AJ35TJ-8S1 User's Manual

Brand: MITSUBISHI
Product model: AJ35TJ-8S1
Name: I/O MODULE
Sort: User's Manual
File language: English
File size: 6.99MB
Input and output points: 2048 points.
Input / output data points: 2048 points.
Program capacity: 30K.
Basic command processing speed (LD command) s:1.0.
Optical data communication line function (GI cable).
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh AJ35TJ-8S1 Manual AJ35TJ-8S1 User's Manual.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read AJ35TJ-8S1
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program AJ35TJ-8S1 Manual AJ35TJ-8S1 User's Manual.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
User program storage capacity: it is a measure of how much the user application can store the number of indicators AJ35TJ-8S1 Manual AJ35TJ-8S1 User's Manual.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General logical operation instructions each account for 1 words. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4. Input type: DC input, positive public end / negative public end.
Input points: 32 points.
Enter the response time: 0.2ms below, below 1.5ms, 5ms below, 10ms the following.
Rated input voltage / current: DC24V/7mA.
External connection:: 1 wire AJ35TJ-8S1 Manual AJ35TJ-8S1 User's Manual.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup.
Finger protection through the upper part of the terminal,,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool AJ35TJ-8S1 Manual AJ35TJ-8S1 User's Manual.
Related products
MITSUBISHI
Analog module
AJ35T-M08B-L
MITSUBISHI Analog module AJ35T-M08B-L
Analog channel: 8 channels. Input / output r
MITSUBISHI
Silicon controlled output module
AJ35TJ-8S2
MITSUBISHI Silicon controlled output module
 AJ35TJ-8S2
Output points: 8 points. Output voltage and c
MITSUBISHI
DC input / transistor output module
AJ35TB1-16DT
MITSUBISHI DC input / transistor output module AJ35TB1-16DT
DC input points: 8 points. Input voltage and
MITSUBISHI
DC input module
AJ35TB1-16D
MITSUBISHI DC input module AJ35TB1-16D
DC input points: 16 points. Input voltage and