MITSUBISHI AJ35TJ-48DT Manual AJ35TJ-48DT User's Manual

Brand: MITSUBISHI
Product model: AJ35TJ-48DT
Name: I/O MODULE
Sort: User's Manual
File language: English
File size: 6.99MB
Input and output points: 2048 points.
Input / output data points: 2048 points.
Program capacity: 30K.
Basic command processing speed (LD command): with 1 s coaxial data communication line function.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process AJ35TJ-48DT Manual AJ35TJ-48DT User's Manual. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read AJ35TJ-48DT
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program AJ35TJ-48DT Manual AJ35TJ-48DT User's Manual.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
User program storage capacity: it is a measure of how much the user application can store the number of indicators AJ35TJ-48DT Manual AJ35TJ-48DT User's Manual.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General logical operation instructions each account for 1 words. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4. Input voltage range: DC24V.
Output voltage: DC5V.
Output current: 2.5A.
I/O points is an important indicator of PLC.
Reasonable selection of I/O points can not only satisfy the control requirements of the system,
And the total investment of the system is the lowest.
The input and output points and types of PLC should be determined according to the analog quantity and switch quantity of the controlled object,
Generally an input / output element to take up an input / output point.
Taking into account the future adjustment and expansion,
In general should be estimated on the total number of points plus the amount of spare 20%~30%.
The following describes the centralized control system I/O points of the estimate.
Relay output interface circuit of PLC
Working process: when the internal circuit output digital signal 1,
There is a current flowing through, the relay coil has a current, and then the normally open contact is closed,
Provide load current and voltage.
When the intternal circuit outputs a digital signal 0, there is no current flowing through it,
The relay coil does not have a current, and the normally open contact is broken off,
A current or voltage that is discoonnected from the load AJ35TJ-48DT Manual AJ35TJ-48DT User's Manual AJ35TJ-48DT Manual AJ35TJ-48DT User's Manual.
It is through the output interface circuit to the internal digital circuit into a signal to make the load action or not action.
Related products
MITSUBISHI
DC input module
AJ35TB3-8D
MITSUBISHI DC input module AJ35TB3-8D
DC input points: 8 points. Input voltage and
MITSUBISHI
Relay output module
AJ35TB1-16R
MITSUBISHI Relay output module
 AJ35TB1-16R
Output points: 16 points. Output voltage and
MITSUBISHI
AC input / relay output module
AJ35TB1-16AR
MITSUBISHI AC input / relay output module AJ35TB1-16AR
AC input points: 8 points. Input voltage and
MITSUBISHI
DC input module
AJ35TB2-16D
MITSUBISHI DC input module AJ35TB2-16D
DC input points: 16 points. Input voltage and