MITSUBISHI AD71S1 Hardware Manual AD71S1 User's Manual

Brand: MITSUBISHI
Product model: AD71S1
Name: Positioning module
Sort: User's Manual (Hardware)
File language: English
File size: 0.33MB
Input voltage range: DC110V.
Output voltage: DC5V.
Output current: 8A.
I/O points is an important indicator of PLC.
Reasonable selection of I/O points can not only satisfy the control requirements of the system,
And the total investment of the system is the lowest.
The input and output points and types of PLC should be determined according to the analog quantity and switch quantity of the controlled object,
Generally an input / output element to take up an input / output point AD71S1 Hardware Manual AD71S1 User's Manual AD71S1
Taking into account the future adjustment and expansion,
In general should be estimated on the total number of points plus the amount of spare 20%~30%.
The following describes the centralized control system I/O points of the estimate AD71S1 Hardware Manual AD71S1 User's Manual. 32 point connector for pressing flat cable (40 pin connector.Input and output points: 512 points.
Input / output data points: 512 points.
Program capacity: 14K.
Basic command processing speed (LD command) s:1.0.
Optical data communication line function (GI cable).
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process AD71S1 Hardware Manual AD71S1 User's Manual. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
User program storage capacity: it is a measure of how much the userr application can store the number of indicators AD71S1 Hardware Manual AD71S1 User's Manual.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General llogical operation instructions each account for 1 words AD71S1 Hardware Manual AD71S1 User's Manual. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.
Related products
MITSUBISHI
Positioning module
AD70D
MITSUBISHI Positioning module AD70D
Output 1 axes. High speed positioning can e
MITSUBISHI
Positioning module
AD75M2
MITSUBISHI Positioning module AD75M2
2 axes. 2 axis linear interpolation, 2 axis a
MITSUBISHI
Positioning module
AD71-S1
MITSUBISHI Positioning module AD71-S1
2 axes. 2 axis linear interpolation. Control
MITSUBISHI
Positioning module
AD71
MITSUBISHI Positioning module AD71
2 axes. 2 axis linear interpolation, 2 axis a