Input and output points: 512 points.
Input / output data points: 512 points.
Program capacity: 14K.
Basic command processing speed (LD command) s:1.0.
User program storage capacity: it is a measure of how much the user application can store the number of indicators.
Usually in words or K words as units A985GOT-TBD-V Hardware Manual A985GOT-TBD-V User's Manual. 16 bit binary number is a word,
Every 1024 words are 1K words
A985GOT-TBD-V PLC to store instructions and data in words.
General logical operation instructions each account for 1 words. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.
Integral type: the PLC components are installed together or a few pieces of printed circuit board,
And together with the power supply installed in the casing to form a single overall called the host or the basic unit, small, ultra small PLC using this structure A985GOT-TBD-V Hardware Manual A985GOT-TBD-V User's Manual.
Modular: PLC is the basic components of a separate module.
Medium and large PLC used this way. Easy maintenance. Input type: DC input, positive public end / negative public end.
Input points: 16 points.
Enter the response time: 0.2ms the following.
Rated input voltage / current: DC24V/5mA A985GOT-TBD-V Hardware Manual A985GOT-TBD-V User's Manual.
External connection: 1 wire.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup.
Finger protection through the upper part of the terminal,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool. 32: terminal line adapter 0.3mm2 (AGW22).Input type: DC input, positive common end.
Input points: 8 points.
Enter the response time: 0.2ms the following.
Rated input voltage / current: DC24V/5mA.
External connection: 3 wire.
Fast connector type.
Simple wiring through quick connector.
Can be installed along the 6 direction.
MITSUBISHI PLC program simulation debugging
The basic idea of prrogram simulation debugging is,
In order to facilitate the form of simulation to generate the actual state of the scene,
Create the necessary environmental conditions for the operation of thee program A985GOT-TBD-V Hardware Manual A985GOT-TBD-V User's Manual A985GOT-TBD-V Hardware Manual A985GOT-TBD-V User's Manual.
Depending on the way the field signals are generated,
The simulation debugging has two forms of hardware simulation and software simulation.