MITSUBISHI A975GOT-TBA-B SW4D5C-GOTR-PACKE compatible Extended/Option Functions Manual Manual A975GOT-TBA-B Operating Manual

Brand: MITSUBISHI
Product model: A975GOT-TBA-B
Name: touch screen
Sort: Operating Manual (SW4D5C-GOTR-PACKE compatible Extended/Option Functions Manual)
File language: English
File size: 3.00MB
CPU connection program input device.
ACPU use. Input type: DC input, positive common end.
Input points: 16 points.
Enter the response time: 0.2ms below, below 1.5ms, 5ms below, 10ms the following.
Rated input voltage / current: DC24V/7mA.
Output form: transistor output, leakage type.
Output points: 16 points A975GOT-TBA-B SW4D5C-GOTR-PACKE compatible Extended/Option Functions Manual Manual A975GOT-TBA-B Operating Manual A975GOT-TBA-B
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC24V/0.5A.
External connection: 1 line /1 line type.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup.
Finger protection through the upper part of the terminal,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool A975GOT-TBA-B SW4D5C-GOTR-PACKE compatible Extended/Option Functions Manual Manual A975GOT-TBA-B Operating Manual. RS-232:1, RS-422/485:1.
Transmission speed: 0.3 ~ 19.2kpbs.
Computer connection function.
So far the system''s hardware electrical circuit has been determined.
Printer / peripheral device connection, BASIC language function.
How to choose MITSUBISHI PLC.
MITSUBISHI PLC options include the choice of MITSUBISHI PLC models, capacity, I/O module, power, etc A975GOT-TBA-B SW4D5C-GOTR-PACKE compatible Extended/Option Functions Manual Manual A975GOT-TBA-B Operating Manual. .
MITSUBISHI PLC distribution I/O points and design MITSUBISHI PLC peripheral hardware circuit
Draw the I/O point of the PLC and the input / output device connection diagram or the corresponding table,
This part also can be carried out in second steps.
Design PLC peripheral hardware circuit.
Draw the electrical wiring diagram of the other parts of the system,
Including the main circuit and the control circuit does not enter the PLC, etc..
The electrical schematic diagram of the system composed of I/O PLC connection diagram and PLC peripheral electrical circuit diagram. Input type: DC input, positive common end.
Input points: 16 points.
Enter the response time: 0.2ms the following.
Rated input voltage / current: DC24V/5mA.
Output form: transistor output, leakage type.
Output points: 16 points.
OFF leakage current: 0.1mA.
Output protection function.
Rated load voltage / current: DC24V/0.1A.
External connection: 1 line /1 line type.
40 pin connector type (FCN connector type).
Through the 40 pin connector type (FCN connector type) can be connected to a variety of devices.
Can be installed along the 6 direction.
Hardware simulation method is to use a number of hardware equipment to simulate the generation of the signal,
The signals are connected to the input end of the PLC system in a hard wired way, and the timeliness is strong.
Software simulation method is in the MITSUBISHI PLC in the preparatioon of a set of simulation program,
The simulation provides the field signal, which is simple and easy to operate, but it is not easy too guarantee the timeliness A975GOT-TBA-B SW4D5C-GOTR-PACKE compatible Extended/Option Functions Manual Manual A975GOT-TBA-B Operating Manual A975GOT-TBA-B SW4D5C-GOTR-PACKE compatible Extended/Option Functions Manual Manual A975GOT-TBA-B Operating Manual.
Simulation of the process of debugging, debugging method can be used to segment, and the monitoring function of programmer.