Position detection axis number: 1 axis.
Resolution: 4096 * 32 ~ 409.6 * 320 rotation (multi turn), 0.0039062mm/256mm ~ 0.015625mm/1024mm (linear type).
Number of output channels: 16 channels.
When communicating in the PLC network of MITSUBISHI,
There is no sense of difference and discontinuity in the network,
Can carry on the remote monitoring, modification, debugging and other work of data communication and program,
Without taking into account the level and type of network A953GOT-SBD Introductory Manual Manual A953GOT-SBD Operating Manual A953GOT-SBD
MELSECNET/H and CC-Link use the way of loop communication,
Periodically automatically send and receive messages,
Does not require specialized data communication procedures,
Simple parameters can be set.
MELSECNET/H and CC-Link are used to transmit and receive the broadcast mode,
This can be done on the network data sharing A953GOT-SBD Introductory Manual Manual A953GOT-SBD Operating Manual.
For the use of Ethernet, MELSECNET/H, CC-Link network,
Can set the network parameters and various functions, simple and convenient in the Developer GX software screen. Cable length: 6 meters
Extending cable to connect CPU main substrate and extended substrate,
According to the model can provide different cable length,
If you need to connect the AnN type expansion substrate is required,
Selection of A1SC05NB (A1SC07NB) cable A953GOT-SBD Introductory Manual Manual A953GOT-SBD Operating Manual. Output type: bidirectional thyristor output.
Output points: 16 points.
OFF leakage current: 1.5mA following (AC100V) below /3mA (AC200V).
Output protection function: No.
Rated load voltage / current: AC100V~240V/0.6A.
External connection: 2 wire.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup.
Finger protection through the upper part of the terminal,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool. 2 axes.
2 axis linear interpolation.
Control unit: pulse, mm, inch, degree.
Determine the location of the number of data: 400/1 axis.
40 pin connector.
Control mode: position automatic acceleration and deceleration time: 64-4999ms pulse train output.
Structured text language is a programming language that describes a program with a structured description of the text.
It is a programming language similar to a high level language. In large and medium
Structured text is often used to describe the relationship between the various variables in the control system based on the PLC system.
Mainly used for other programming languages more difficult to achieve the user program.
Sequential function flow chart language is designed to satisfy the sequential logic control.
The process of sequential process action is divided into steps and transformation conditions,
According to the transfer condition, the control system is distributed in the function flow sequence,
Step by step according to the sequence of actions.
Each step represents a control function, represented by the box.
In the box, the ladder logic is used to complete the task of the corresponding control function.
This programming language makes the program structure clear and easy to read and maintain,
Greatly reduce the programming workload, shorten the programming and debugging time.
Used in the system of the size of the school, procedures for more complex occasions.
Sequence function flow chart programming language features: to function as the main line, in accordance with the functional flow of the order of distribution, clear, easy to understand the user program,
Avoid the defect of ladder diagram or other languages,
At the same time, the use of ladder language to avoid the use of ladder programming,
Due to the complicated mechanical interlock, the structure of the user program is complex and difficult to understand,
User program scan time is also greatly reduced.
A1SD75 series components show MITSUBISHI in manufacturing and design CNC,
Integrated technical experience in the aspects of frequency converter, servo system and PLC.
Thesee components have a wealth of features that are sufficient to meet the highest requirements in the application of positioning control A953GOT-SBD Introductory Manual Manual A953GOT-SBD Operating Manual.
Up to 3 axis linkage operation,
In low cost mootion control applications, this component can be used to control the operation of a multi - to 3 axis, which can be used to account for only one slot A953GOT-SBD Introductory Manual Manual A953GOT-SBD Operating Manual.
Related products
MITSUBISHI
6 inch man machine interface
A953GOT-TBD
MITSUBISHI 6 inch man machine interface A953GOT-TBD
Series Name: A953GOT. Size: 6 inches. Resolut
MITSUBISHI
6 inch man machine interface
A953GOT-SBD
MITSUBISHI 6 inch man machine interface A953GOT-SBD
Series Name: A953GOT. Size: 6 inches. Resolut
MITSUBISHI
6 inch man machine interface
A951GOT-SBD
MITSUBISHI 6 inch man machine interface A951GOT-SBD
Series Name: A951GOT. Size: 6 inches. Resolut