Name: MELSECNET/10 INTERFACE BOARD
Sort: User's Manual
File language: English
File size: 1.85MB
Analog RGB input system.
Applicable model: A985GOT-V. Input and output points: 2048 points.
Input / output data points: 2048 points.
Program capacity: 30K.
Basic command processing speed (LD command) s:1.0.
Optical data communication line.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh A7BDE-J71LP21 Manual A7BDE-J71LP21 User's Manual.
Input refresh process A7BDE-J71LP21 When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program A7BDE-J71LP21 Manual A7BDE-J71LP21 User's Manual.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
User program storage capacity: it is a measure of how much the user application can store the number of indicators A7BDE-J71LP21 Manual A7BDE-J71LP21 User's Manual.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General logical operation instructions each account for 1 words. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4. Number of channels: 4 channels
Sensing method and temperature range: PT100
A1S64TC series component is a kind of temperature controller combined with ANS series CPU.
Components with temperatuure measurement input and built-in PID algorithm control output,
Can be used in a variety of temperature control occasions A7BDE-J71LP21 Manual A7BDE-J71LP21 User's Manual.
Each component controls up to 4 loops at most.
Thermocouple input or PT100 3 wire temperature sensor input A7BDE-J71LP21 Manual A7BDE-J71LP21 User's Manual.
Control output switching signal for the output of the transistor.
BW is a signal with broken line detection function.