MITSUBISHI
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI A70BDE-J71QBR13 For SW3DNF-MNET10 Manual A70BDE-J71QBR13 User's Manual

MITSUBISHI A70BDE-J71QBR13 For SW3DNF-MNET10 Manual A70BDE-J71QBR13 User's Manual

Brand: MITSUBISHI
Product model: A70BDE-J71QBR13
Name: MELSECNET/10 Interface Board
Sort: User's Manual (For SW3DNF-MNET10)
File language: English
File size: 2.12MB
Number of channels: 4 channels.
Sensing methods and temperature range: R, K, J, T, S, B, E, N, U, L, PL, II,, Wre5-26,,, and.
A1S64TC series component is a kind of temperature controller combined with ANS series CPU.
Components with temperature measurement input and built-in PID algorithm control output,
Can be used in a variety of temperature control occasions A70BDE-J71QBR13 For SW3DNF-MNET10 Manual A70BDE-J71QBR13 User's Manual A70BDE-J71QBR13
Each component controls up to 4 loops at most,
Thermocouple input or PT100 3 wire temperature sensor input,
Control output switching signal for the output of the transistor,
BW is a signal with broken line detection function. Input type: DC input, positive public end / negative public end.
Input points: 16 points.
Enter the response time: 0 A70BDE-J71QBR13 For SW3DNF-MNET10 Manual A70BDE-J71QBR13 User's Manual. 2ms the following.
Rated input voltage / current: DC24V/5mA.
External connection: 1 wire.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup.
Finger protection through the upper part of the terminal,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool A70BDE-J71QBR13 For SW3DNF-MNET10 Manual A70BDE-J71QBR13 User's Manual. Output type: transistor source / drain type.
Output points: 8 points.
Load voltage: DC5/12/24/48.
Load current: 2A.
Connection mode: terminal row.
Common public end points: 1.
Switching value, also known as logic, refers to only two values, 0 or 1, ON or OFF.
It is the most common control, it is the advantage of PLC control,
Is also the most basic application of PLC.
Switch volume control is designed to,
According to the current input combination of the switch quantity and the history of the input sequence,
So that PLC generates the corresponding switching output,
In order to make the ssystem work in a certain order A70BDE-J71QBR13 For SW3DNF-MNET10 Manual A70BDE-J71QBR13 User's Manual.
So, sometimes also known as the order control.
And sequential control is divided into manual, semi-automatic or automatic.
And the control principple is decentralized, centralized and hybrid control three A70BDE-J71QBR13 For SW3DNF-MNET10 Manual A70BDE-J71QBR13 User's Manual. A set of 5 (LOGO removable, man-machine interface provides one).
Applicable model: A960GOT.