276此ID下载地址不存在3--/downloadfile/259-MELSEC-A-series-programmable-controllers(UL-standard-approved-equipment)-f.pdf MITSUBISHI A3NMACA2-UL Manual A3NMACA2-UL User's Manual - MITSUBISHI
MITSUBISHI
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI A3NMACA2-UL Manual A3NMACA2-UL User's Manual

MITSUBISHI A3NMACA2-UL Manual A3NMACA2-UL User's Manual

Brand: MITSUBISHI
Product model: A3NMACA2-UL
Name: PLC
Sort: User's Manual
File language: English
File size: 0.00MB
Optional features of memory card (A/FX compatible).
8MB extended memory.
Applicable models: A985 (-V) /975/970/A960GOT (-B) /A956WGOT. Available network: Profibus-DP.
Function: Master station.
The A1SJ71PB96F and A1SJ71PB92D modules allow a PLC ANS to connect to the Profibus system,
Meet the CE standard, using SWOIX/ProfiMap special programming software A3NMACA2-UL Manual A3NMACA2-UL User's Manual A3NMACA2-UL
A1SJ71PB96F compatible with Profibus-FMS, as a master or client;
A1SJ71PB92D compatible with Profibus-DP, can be used as a master to control the remote Profibus-DP I/O. MITSUBISHI PLC hardware implementation
Hardware implementation is mainly for the control cabinet and other hardware design and field construction.
Design control cabinet and the operating table and other parts of the electrical wiring diagram and wiring diagram A3NMACA2-UL Manual A3NMACA2-UL User's Manual.
Electrical interconnection diagram of each part of the design system.
According to the construction drawings of the site wiring, and carry out a detailed inspection.
Because the program design and hardware implementation can be carried out at the same time,
So the design cycle of the MITSUBISHI PLC control system can be greatly reduced A3NMACA2-UL Manual A3NMACA2-UL User's Manual. Output points: 32 points.
Voltage: DC24V/AC240V, 2A/1 point, 5A/1 public end.
Output type: relay output.
Response time: 12ms.
8 point /1 a public side.
38 point terminal station.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc..
In general, a reversible DC drive system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid vvalve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points A3NMACA2-UL Manual A3NMACA2-UL User's Manual A3NMACA2-UL Manual A3NMACA2-UL User's Manual.