Brand: MITSUBISHI
Product model: A2SHCPU-S1
Name: Programmable Logic Controller
Sort: Programming Manual (Common Instructions)
File language: English
File size: 3.29MB
Output type: transistor output, source.
Output points: 32 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC12V/DC24V/0.5A.
External connection: 1 wire.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup A2SHCPU-S1 Common Instructions Manual A2SHCPU-S1 Programming Manual A2SHCPU-S1
Finger protection through the upper part of the terminal,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool. Input type: DC input, positive common end.
Input points: 8 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/5mA A2SHCPU-S1 Common Instructions Manual A2SHCPU-S1 Programming Manual .
Output form: transistor output, leakage type.
Output points: 8 points.
OFF leakage current: 0.25mA.
Output protection function.
Rated load voltage / current: DC24V/0.5A.
External connection: 4 wire.
Fast connector type.
Simple wiring through quick connector.
Can be installed along the 6 direction.
MITSUBISHI PLC program simulation debugging
The basic idea of program simulation debugging is,
In order to facilitate the form of simulation to generate the actual state of the scene,
Create the necessary environmental conditions for the operation of the program A2SHCPU-S1 Common Instructions Manual A2SHCPU-S1 Programming Manual .
Depending on the way the field signals are generated,
The simulation debugging has two forms of hardware simulation and software simulation. Analog channel: 12 channels.
Input / output (resolution): 0 ~ 4000.
Conversion speed: 100ms/12 channel.
Analog module installation.
Power supply: DC24V.
According to the control requirements of the system, using the appropriate design method to design MITSUBISHI PLC program.
Procedures to meet the requirements of system control as the main line,
Write one by one to achieve the control function or the sub task of the program,
Gradually improve the functions specified by the system.
MITSUBISHI PLC detection, fault diagnosis and display and other procedures.
These procedures are relatively independent, generally in the basic completion of the program design and then add.
Hardware simulation method is to use a number of hardware equipment to simulate the generation of the signal,
The signals are connected to the input end of the PLC system in a hard wired way, and the timeliness is strong.
Software simulation methhod is in the MITSUBISHI PLC in the preparation of a set of simulation program,
The simulation provides the field signal, which is simple and easy to operate, but it is not easy too guarantee the timeliness A2SHCPU-S1 Common Instructions Manual A2SHCPU-S1 Programming Manual A2SHCPU-S1 Common Instructions Manual A2SHCPU-S1 Programming Manual .
Simulation of the process of debugging, debugging method can be used to segment, and the monitoring function of programmer.
Related products
MITSUBISHI
CPU unit
A2NCPU-S1
MITSUBISHI CPU unit A2NCPU-S1
Input and output points: 1024 points. Input /
MITSUBISHI
CPU unit
Q2ACPU-S1
MITSUBISHI CPU unit Q2ACPU-S1
Input and output points: 1024 points. Input /
MITSUBISHI
CPU unit
A2ACPU-S1
MITSUBISHI CPU unit A2ACPU-S1
Input and output points: 1024 points. Input /
MITSUBISHI
Moving CPU unit
A73CPU-S1
MITSUBISHI Moving CPU unit A73CPU-S1
Multi axis positioning controller. Program ca