MITSUBISHI
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI A2NCPUP21 Fundamentals Manual A2NCPUP21 Programming Manual

MITSUBISHI A2NCPUP21 Fundamentals Manual A2NCPUP21 Programming Manual

Brand: MITSUBISHI
Product model: A2NCPUP21
Name: PLC
Sort: Programming Manual (Fundamentals)
File language: English
File size: 8.33MB
Input points: 16 points.
Input voltage and current: 3/7mA DC12/24V.
Input response time: 10ms.
16 point /1 a public side.
Positive and negative sharing.
Output points: 16 points.
Output voltage: DC24V.
OFF leakage current: 0.1mA.
Output response time: 2ms.
16 point /1 a public side.
Output type: transistor output (type sink) A2NCPUP21 Fundamentals Manual A2NCPUP21 Programming Manual.
With the surge absorber A2NCPUP21
50 point terminal station.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal A2NCPUP21 Fundamentals Manual A2NCPUP21 Programming Manual.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc..
In general, a reversible DC drive system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points A2NCPUP21 Fundamentals Manual A2NCPUP21 Programming Manual.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points A2NCPUP21 Fundamentals Manual A2NCPUP21 Programming Manual A2NCPUP21 Fundamentals Manual A2NCPUP21 Programming Manual.
Related products
MITSUBISHI
CPU unit
A2NCPUP21
MITSUBISHI CPU unit A2NCPUP21
Input and output points: 512 points. Input /
MITSUBISHI
CPU unit
A2NCPUP21-S1
MITSUBISHI CPU unit A2NCPUP21-S1
Input and output points: 1024 points. Input /
MITSUBISHI
CPU unit
A1NCPUP21
MITSUBISHI CPU unit A1NCPUP21
Input and output points: 256 points. Input /
MITSUBISHI
CPU unit
A2NCPU
MITSUBISHI CPU unit A2NCPU
Input and output points: 512 points. Input /