10BASE-T.
When communicating in the PLC network of MITSUBISHI,
There is no sense of difference and discontinuity in the network,
Can carry on the remote monitoring, modification, debugging and other work of data communication and program,
Without taking into account the level and type of network.
MELSECNET/H and CC-Link use the way of loop communication,
Periodically automatically send and receive messages,
Does not require specialized data communication procedures,
Simple parameters can be set A2ASCPU-S30 Fundamentals Manual A2ASCPU-S30 Programming Manual
A2ASCPU-S30
MELSECNET/H and CC-Link are used to transmit and receive the broadcast mode,
This can be done on the network data sharing.
For the use of Ethernet, MELSECNET/H, CC-Link network,
Can set the network parameters and various functions, simple and convenient in the Developer GX software screen A2ASCPU-S30 Fundamentals Manual A2ASCPU-S30 Programming Manual. 16 channels.
Input: DC-10 ~ 10V, DC-20 ~ 20mA.
Output (resolution): 0 ~ 4000, 0 ~ 8000, 0 ~ 12000.
38 point terminal station.
Analog I/P multiplexing unit.
Detailed analysis of the process and work characteristics of the controlled object,
To understand the coordination between the controlled object machine, electricity and liquid,
The control requirements of the controlled object for MITSUBISHI PLC control system are put forward,
Determine the control program, to develop a design task book A2ASCPU-S30 Fundamentals Manual A2ASCPU-S30 Programming Manual.
How to determine the input / output device of MITSUBISHI plc.
According to the control requirements of the system,
All input devices and output devices required for the determination of the system,
To determine the input / output device related to the MITSUBISHI PLC,
To determine the I/O PLC points. A set of 5 (LOGO removable, man-machine interface provides one).
Applicable model: A985GOT (-V). Input type: DC input, positive / negative public end.
Input points: 8 points.
Enter the response time: 0.2ms below, below 1.5ms, 5ms below, 10ms the following.
Rated input voltage / current: DC12V/7mA.
Output form: relay output.
Output points: 8 points.
OFF leakage current: -.
Output protection function: No.
Rated load voltage / current: DC24V/AC240V/0.5A.
External connection: 3 line /2 line type.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup A2ASCPU-S30 Fundamentals Manual A2ASCPU-S30 Programming Manual.
Finger protection through the upper part of the terminal,,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool A2ASCPU-S30 Fundamentals Manual A2ASCPU-S30 Programming Manual.