MITSUBISHI
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI A273UCPU Dedicated Instructions Manual A273UCPU Programming Manual

MITSUBISHI A273UCPU Dedicated Instructions Manual A273UCPU Programming Manual

Brand: MITSUBISHI
Product model: A273UCPU
Name: PLC
Sort: Programming Manual (Dedicated Instructions)
File language: English
File size: 17.11MB
Write adapter for EPROM 28 pinInput type: DC input, positive / negative public end.
Input points: 8 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/7mA.
Output form: relay output.
Output points: 8 points.
OFF leakage current: -.
Output protection function: No A273UCPU Dedicated Instructions Manual A273UCPU Programming Manual.
Rated load voltage / current: DC24V/AC240V/2A A273UCPU
External connection: 3 line /2 line type.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup.
Finger protection through the upper part of the terminal,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool A273UCPU Dedicated Instructions Manual A273UCPU Programming Manual. Series Name: A975GOT.
Size: 10 inches.
Resolution: 600 * 480.
Display equipment: high brightness TFT color display.
Display color: 16 color.
Power supply: DC24V.
Memory card: 1M.
Man machine interface is the interface between man and machine in the field of information exchange and function contact or influence,
Information exchange, functional contact or mutual influence, the hard contact and soft touch of a person and machine,
This interface includes not only the direct contact point line side,
It also includes the function of remote information transmission and control A273UCPU Dedicated Instructions Manual A273UCPU Programming Manual.
The man-machine interface is the central link in the man-machine system,
Mainly from the safety engineering branch of the safety ergonomics to study and put forward the basis for the solution,
And over the safety engineering equipment engineering, safety management engineering and safety systems engineering to study the specific solutions and measures to the safety of human computer science and technology.
It realizes the transformation between the internal form of information and the acceptable form of human being. Pulse input: differential input.
Preset input: differential input.
Count range: 0~16777215.
Number of stations: 4 stops.
Station type: remote equipment station.
Configuration of master / local station,
In addition to the other site network with different CC-Link in addition to the main station and the remote station configuration can also be the main station and the local station configuration.
A local PLC can communicate with the master station PLC and other remote workstations.
MITSUBISHI PLC hardware implementation
Hardware implementation is mainly for the control cabinet and other hardware design and field construction.
Design control cabinet and the operating table and other parts of the electrical wiring diagram and wiring diagram.
Electrical interconnection diagram of each part of the design system.
According to the construction drawings of the site wiring, and carry out a detailed inspection.
Because the program design and hardware implementation can be carried out at the same time,
So the design cycle of the MITSUBISHI PLC control system can be greatly reduced.
MITSUBISHI PLC online debugging.
On-line debugging is the process that will through the simulation debugging to further carry on the on-line unification to adjust.
On-line debugging proccess should be step by step,
From MITSUBISHI PLC only connected to the input device, and then connect the output device, and then connect to the actual load and so on and so on stepp by step A273UCPU Dedicated Instructions Manual A273UCPU Programming Manual A273UCPU Dedicated Instructions Manual A273UCPU Programming Manual.
If you do not meet the requirements, the hardware and procedures for adjustment.
Usually only need to modify the part of the program can be.