MITSUBISHI A1SJ71ID2-R4 Manual A1SJ71ID2-R4 User's Manual

Brand: MITSUBISHI
Product model: A1SJ71ID2-R4
Name: ID Interface Module
Sort: User's Manual
File language: English
File size: 5.23MB
Screw terminal table type.
Voltage / current output module.
Number of channels: 2 channels.
Number of stations: 1 stops.
Station type: remote equipment station.
MITSUBISHI PLC hardware implementation
Hardware implementation is mainly for the control cabinet and other hardware design and field construction A1SJ71ID2-R4 Manual A1SJ71ID2-R4 User's Manual.
Design control cabinet and the operating table and other parts of the electrical wiring diagram and wiring diagram A1SJ71ID2-R4
Electrical interconnection diagram of each part of the design system.
According to the construction drawings of the site wiring, and carry out a detailed inspection.
Because the program design and hardware implementation can be carried out at the same time,
So the design cycle of the MITSUBISHI PLC control system can be greatly reduced A1SJ71ID2-R4 Manual A1SJ71ID2-R4 User's Manual.
MITSUBISHI PLC online debugging.
On-line debugging is the process that will through the simulation debugging to further carry on the on-line unification to adjust.
On-line debugging process should be step by step,
From MITSUBISHI PLC only connected to the input device, and then connect the output device, and then connect to the actual load and so on and so on step by step A1SJ71ID2-R4 Manual A1SJ71ID2-R4 User's Manual.
If you do not meet the requirements, the hardware and procedures for adjustment.
Usually only need to modify the part of the program can be. Output type: relay output.
Output points: 16 points.
OFF leakage current: -.
Output protection function: No.
Rated load voltage / current: DC24V/AC240V/2A.
External connection: 2 wire.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup.
Finger protection through the upper part of the terminal,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool. Two slots in one side.
Power supply unit.
Q4AR duplex system.
Switch volume control is designed to,
According to the current input combination of the switch quantity and the history of the input sequence,
So that PLC generates the corresponding switching output,
In order to make the system work in a certain order.
So, sometimes also known as the order control.
And sequential control is divided into manual, semi-automatic or automatic.
And the control principle is decentralized, centralized and hybrid control three.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / outpuut hysteresis phenomena, i A1SJ71ID2-R4 Manual A1SJ71ID2-R4 User's Manual. e., the input / output response delay.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program tto do the compiler to compile the process of interpretation A1SJ71ID2-R4 Manual A1SJ71ID2-R4 User's Manual.
Read only memory. Manufacturers use, content can not be changed, power does not disappear.
Related products
MITSUBISHI
Ethernet module
A1SJ71E71N-B5
MITSUBISHI Ethernet module A1SJ71E71N-B5
10BASE5. PLC is introduced y the relay contr
MITSUBISHI
Modem module
A1SJ71CMO-S3
MITSUBISHI Modem module A1SJ71CMO-S3
Using a modem middle modular connector unit f
MITSUBISHI
Melsecnet interface module
A1SJ71AP21-S3
MITSUBISHI Melsecnet interface module A1SJ71AP21-S3
PLC station distance: 2Km. Cale type: GI-50/