MITSUBISHI
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI A0J2CPU-DC24 Manual A0J2CPU-DC24 Programming Manual

MITSUBISHI A0J2CPU-DC24 Manual A0J2CPU-DC24 Programming Manual

Brand: MITSUBISHI
Product model: A0J2CPU-DC24
Name: PLC
Sort: Programming Manual
File language: English
File size: 3.56MB
Input type: DC input, positive common end.
Input points: 4 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/7mA.
Output form: transistor output, leakage type.
Output points: 4 points.
OFF leakage current: 0.25mA.
Output protection function.
Rated load voltage / current: DC24V/0 A0J2CPU-DC24 Manual A0J2CPU-DC24 Programming Manual. 5A.
External connection: 3 line /2 line type A0J2CPU-DC24
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup.
Finger protection through the upper part of the terminal,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool A0J2CPU-DC24 Manual A0J2CPU-DC24 Programming Manual. Input type: DC input, positive public end / negative public end.
Input points: 32 points.
Enter the response time: 10ms the following.
Rated input voltage / current: DC24V/5mA.
External connection: 1 wire.
A2C shape terminal.
Type of input and output terminal.
Shape and A2C input and output modules are identical (same mounting dimensions),
Machining and installing holes are not required A0J2CPU-DC24 Manual A0J2CPU-DC24 Programming Manual. 16 channels.
Input (resolution): -4000 ~ 4000.
Output: DC-5 ~ 5V, DC10 ~ 10.
Conversion speed: 0.5ms * channel number +2ms.
38 point terminal station.
Input status and input information input from the input interface,
CPU will be stored in the working data memory or in the input image register.
And then combine the data and the program with CPU.
The result is stored in the output image register or the working data memory,
And then output to the output interface, control the external drive.
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive.
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference. Therefore PLC selection,
Under the premise of meeting the control requirements,
Should consider the best performance to price ratio, a reasonable choice of PLC.
The working process of the input interface circuit: when the switch is closed, the diode light,
The transistor is then guided to the internal circuit and input signal under the irradiation of the light.
When the switch is off, the diode does not emit light, and the transistor is not on the way. Internal circuit input signal.
It is through the input interface circuit to the external switch signal into PLC internal can accept the digital signal.
MITSUBISHI PLC is the main productt in the production of MITSUBISHI motor in Dalian A0J2CPU-DC24 Manual A0J2CPU-DC24 Programming Manual.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithhmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process A0J2CPU-DC24 Manual A0J2CPU-DC24 Programming Manual.
Related products
MITSUBISHI
CPU unit
A0J2HCPU-DC24
MITSUBISHI CPU unit A0J2HCPU-DC24
Input and output points: 480 points. Input /
MITSUBISHI
CPU unit
A0J2CPU-DC24-S2
MITSUBISHI CPU unit A0J2CPU-DC24-S2
Input and output points: 480 points. Program
MITSUBISHI
CPU unit
A0J2CPU
MITSUBISHI CPU unit A0J2CPU
Input and output points: 480 points. Program
MITSUBISHI
CPU unit
A0J2CPUR23
MITSUBISHI CPU unit A0J2CPUR23
Input and output points: 480 points. Program