MITSUBISHI A0J2-E28DS Manual A0J2-E28DS User's Manual

Brand: MITSUBISHI
Product model: A0J2-E28DS
Name: Input/Output Module
Sort: User's Manual
File language: English
File size: 2.84MB
Input and output points: 2048 points.
Input / output data points: 2048 points.
Program capacity: 30K.
Basic command processing speed (LD command) s:1.0.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read A0J2-E28DS Manual A0J2-E28DS User's Manual A0J2-E28DS
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three A0J2-E28DS Manual A0J2-E28DS User's Manual.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
User program storage capacity: it is a measure of how much the user application can store the number of indicators.
Usually in words or K words as units A0J2-E28DS Manual A0J2-E28DS User's Manual. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General logical operation instructions each account for 1 words. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4. MELSECNET/MINI (-S3) data link system, A2C system transfer converter.
Twisted pair cable -GI optical fiber cable.
MITSUBISHI PLC protection and chain procedures.
Protection and chain is an indispensable part of the program, must be carefully considered.
It can avoid the control logic confusion caused by illegal operations.
MITSUBISHI PLC initialization procedure. After MITSUBISHI PLC on power, the general need to do some of the initial operation,
In order to start making necessary preparations, to avoid the wrong operation of the system.
The main contents of the initialization program are: to some data area, counter and so on,
Data needed to restore some of the data area,
Set or reset some relays,
For some initial state display, etc..
MITSUBISHI PLC program simulation debugging
The baasic idea of program simulation debugging is,
In order to facilitate the form of simulation to generate the actual state of the scene,
Create the necessary environmental conditions for the operation of thee program A0J2-E28DS Manual A0J2-E28DS User's Manual A0J2-E28DS Manual A0J2-E28DS User's Manual.
Depending on the way the field signals are generated,
The simulation debugging has two forms of hardware simulation and software simulation.
Related products
MITSUBISHI
DC input / relay output module
A0J2-E56DR
MITSUBISHI DC input / relay output module A0J2-E56DR
Input points: 32 points. Input voltage and cu
MITSUBISHI
Analog input module
A0J2-68AD
MITSUBISHI Analog input module A0J2-68AD
8 channels. Input: DC-10 10V, DC4 20mA. O
MITSUBISHI
Connecting cable
A0J2-C03F
MITSUBISHI Connecting cable A0J2-C03F
A0J2 56. Input / output unit 2 MITSUBISHI PLC
MITSUBISHI
DC input / relay output module
A0J2-E28DR
MITSUBISHI DC input / relay output module A0J2-E28DR
Input points: 16 points. Input voltage and cu