MITSUBISHI A0J2-C214S1 Manual A0J2-C214S1 User's Manual

Brand: MITSUBISHI
Product model: A0J2-C214S1
Name: PLC
Sort: User's Manual
File language: English
File size: 14.10MB
Output type: transistor drain.
Output points: 16 points.
Load voltage: DC12/24.
Load current: 0.1A.
Connection mode: terminal row.
Common public end points: 8.
Structured text language is a programming language that describes a program with a structured description of the text.
It is a programming language similar to a high level language A0J2-C214S1 Manual A0J2-C214S1 User's Manual. In large and medium
Structured text is often used to describe the relationship between the various variables in the control system based on the PLC system A0J2-C214S1
Mainly used for other programming languages more difficult to achieve the user program.
The structured text programming language uses the computer description method to describe the various kinds of relations between the various variables in the system,
Complete the required function or operation A0J2-C214S1 Manual A0J2-C214S1 User's Manual.
Most PLC manufacturers use structured text programming language similar to BASIC language, PASCAL language or C language and other advanced languages,
But in order to be convenient, the expression methods of the statement and the types of statements are simplified.
Structured text programming language features: the use of high-level language programming, you can complete the complex control operations,
Need to have a certain level of computer knowledge and programming skills,
Higher requirements for engineering designers A0J2-C214S1 Manual A0J2-C214S1 User's Manual. Poor visibility and operability. DC input points: 16 points.
Input voltage and current: 5mA, DC24V.
Response time: 10ms.
16 point /1 a public side.
Positive / negative sharing.
Output points: 16 points.
Output voltage and current: DC24V, 0.1A/1 point, 1.6A/1 common end.
Response time: 2ms.
16 point /1 a public side.
Output form: transistor output, leakage type.
40 pin connector.
Number of stations: 4 stops.
According to the control requirements of the system, using the appropriate design method to design MITSUBISHI PLC program.
Procedures to meet the requirements of system control as the main line,
Write one by one to achieve the control function or the sub task of the program,
Gradually improve the functions specified by the system.
MITSUBISHI PLC detection, fault diagnosis and display and other procedures.
These procedures are relatively independent, generally in the basic completion of the program design and then add.
Hardware simulation method is to use a number of hardware equipment to simulate the generation of the signal,
The signals are connected to the input end of the PLC system in a hard wired way, and the timeliness is strong.
Sooftware simulation method is in the MITSUBISHI PLC in the preparation of a set of simulation program,
The simulation provides the field signal, which is simple and easy to operate, but it is not easy too guarantee the timeliness A0J2-C214S1 Manual A0J2-C214S1 User's Manual A0J2-C214S1 Manual A0J2-C214S1 User's Manual.
Simulation of the process of debugging, debugging method can be used to segment, and the monitoring function of programmer.
Related products
MITSUBISHI
Connecting cable
A0J2-C10B
MITSUBISHI Connecting cable A0J2-C10B
A65B/A68B/A55B/A58B connection cale. Length:
MITSUBISHI
DC input / silicon controlled output module
A0J2-E56DS
MITSUBISHI DC input / silicon controlled output module A0J2-E56DS
Input points: 32 points. Input voltage and cu
MITSUBISHI
DC input module
A0J2-E32D
MITSUBISHI DC input module A0J2-E32D
Input points: 32 points. Voltage: DC12/24V. C
MITSUBISHI
AC input / silicon controlled output module
A0J2-E28AS
MITSUBISHI AC input / silicon controlled output module A0J2-E28AS
Input points: 16 points. Input voltage and cu